Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Ana Sayfa / Ürünler / Cleanroom Air Filters / Terminal HEPA Filter Housing Slim with 10 in Collar
STJH-TERMINAL-HEPA-HOUSING-SLIM-10IN

Terminal HEPA Filter Housing Slim with 10 in Collar

A lightweight low-profile terminal integrating a thin HEPA pack, round collar and diffusion disc for shallow plenums.
  • 4.75 in overall depth
  • 10 in round collar
  • Integrated 41 mm HEPA pack
Alıntı isteği Browse ürünleri

Ürün tanıtımı

With an overall depth of 4.75 in, this module is substantially shallower than a separate filter box and full-depth HEPA. A 41 mm filter pack, 10 in round collar and diffusion disc are integrated into an extruded aluminum frame for 1.5 or 2 in T-bar grids. The compact assembly is intended for low interstitial spaces, but duct velocity, terminal airflow and ceiling support must be checked because the shallow plenum offers limited room for distribution.

Ana Özellikler

Very shallow assembly

The integrated filter and diffuser reduce the vertical space required above the ceiling.

Light aluminum frame

Extruded construction lowers terminal mass and fits common cleanroom T-bar arrangements.

Built-in diffusion disc

An internal disc helps distribute air entering from the round collar across the thin filter face.

Teknik parametreler

Overall Depth4.75 in
Filter Pack Depth41 mm
Duct Connection10 in round collar
Frame MaterialExtruded aluminum
Ceiling Grid1.5 or 2 in T-bar
Air DistributionIntegrated diffusion disc
Filter TypeLow-profile terminal HEPA module
AccessRoom-side face
Installation DutyShallow ceiling plenum
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Applications

For medical suites, clean-process rooms and laboratories where shallow interstitial height prevents the use of a conventional deep terminal housing.

Solutions for Your Application

High collar velocity creates nonuniform flow across the thin filter pack.Keep terminal airflow within the selected module rating and provide a suitable upstream branch and balancing damper.
The ceiling grid carries the terminal without adequate independent support.Coordinate hangers and seismic or local support requirements for the actual ceiling system and module mass.

Mevcut Seçenekler

Confirm module face size, 10 in collar position, ceiling grid width, airflow, balancing device, room-side test access and surface finish.

Planning a Terminal HEPA Filter Housing Slim with 10 in Collar specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun