Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Ana Sayfa / Ürünler / Cleanroom Air Filters / Side-Access HEPA Filter Housing Crank-Seal
STJH-SIDE-ACCESS-HEPA-HOUSING-CRANK

Side-Access HEPA Filter Housing Crank-Seal

A side-service HEPA cabinet with a spring-loaded crank mechanism for consistent row-wide gasket compression.
  • Over 700 lb row sealing force
  • Spring-loaded crank action
  • Hinged dual-access doors
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The defining feature of this housing is its spring-loaded crank mechanism, which applies more than 700 lb of sealing force across each filter row. That centralized action helps produce consistent gasket compression and simplifies release compared with tightening multiple independent fasteners. The 14-gauge galvanized cabinet includes hinged dual-access doors and a nominal 2 in prefilter track for final-filter protection.

Ana Özellikler

Uniform row compression

The crank transfers controlled mechanical force across the installed filter rather than relying on hand-tightened points.

Fast service release

One operating mechanism disengages the filter row for withdrawal through the side door.

Protected final stage

A shallow prefilter track captures coarse loading before it reaches the HEPA element.

Teknik parametreler

Housing Material14-gauge galvanized steel
Sealing MechanismSpring-loaded crank
Sealing ForceMore than 700 lb per filter row
AccessHinged dual-access doors
Prefilter Track2 in nominal
Filter SealGasket compression
OperationSide-mounted crank actuation
Primary FilterFull-size HEPA or ULPA element as selected
Service RequirementCrank and spring inspection during filter change
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Applications

For HEPA or ULPA installations where repeatable gasket loading, quick side service and reliable clamping force are priorities.

Solutions for Your Application

Uneven manual tightening leaves a leak path around one corner of the filter.Use the spring-loaded crank to distribute the documented row force and verify seal integrity after installation.
The crank cannot be operated because pipework blocks its sweep.Show the handle path and service clearance on the coordination drawing before locating adjacent utilities.

Mevcut Seçenekler

Specify filter size and depth, cabinet finish, crank side, prefilter, door handing, test ports, gasket material and duct flanges.

Planning a Side-Access HEPA Filter Housing Crank-Seal specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.