Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Ana Sayfa / Ürünler / Containment & Biosafety Equipment / Negative-Pressure Isolation Room Unit 475 CFM Portable
STJH-NEGATIVE-PRESSURE-ISOLATION-ROOM-UNIT-475CFM

Negative-Pressure Isolation Room Unit 475 CFM Portable

A floor-standing H14 HEPA unit with 150–475 CFM adjustment for rapid negative-pressure patient-room conversion.
  • 150–475 CFM adjustment
  • Portable floor-standing format
  • H14 final filtration
Alıntı isteği Browse ürünleri

Ürün tanıtımı

This portable unit covers small and medium isolation-room duties without permanent mounting. Its broad variable-airflow range lets staff establish the required room air balance, while the lower settings reduce sound when full 475 CFM output is unnecessary.

Ana Özellikler

Rapid room conversion

The wheeled enclosure can be positioned for temporary isolation without rebuilding the room air system.

Wide airflow control

Output can be matched to room volume instead of operating continuously at peak flow.

Low-setting acoustics

Published sound spans 38–59 dBA at 1.5 m across the operating range.

Teknik parametreler

Airflow Range150–475 CFM
Final FilterH14 HEPA, nominal 99.995% at 0.3 µm
Sound Level38–59 dBA at 1.5 m
MountingPortable floor-standing
Operating ModesNegative-pressure exhaust or in-room filtration
Approximate Room VolumeUp to about 2500–3000 ft³ at 12 ACH, depending on configuration
Hava akışı kontrolüVariable
Discharge InterfaceConfigurable filtered-air connection
Primary UseTemporary patient-room isolation
Customization (Özelleşme)Duct adapter, discharge route and mobility accessories can be configured for the room layout.

Applications

Emergency patient isolation, infection-control surge rooms and temporary negative-pressure conversion in hospitals or clinics.

Solutions for Your Application

A standard room must become an isolation space quickly.Position the portable unit, establish a controlled discharge path and balance airflow to the room.
Peak airflow creates unnecessary noise in a smaller room.Set output to the airflow needed for the target air-change rate rather than defaulting to 475 CFM.

Mevcut Seçenekler

Flexible ducting, window or wall discharge adapters and mobility accessories can be selected for the room.

Planning a Negative-Pressure Isolation Room Unit 475 CFM Portable specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat