Главная / Продукция / Containment & Biosafety Equipment / Negative-Pressure Isolation Room Unit 475 CFM Portable
STJH-NEGATIVE-PRESSURE-ISOLATION-ROOM-UNIT-475CFM

Negative-Pressure Isolation Room Unit 475 CFM Portable

A floor-standing H14 HEPA unit with 150–475 CFM adjustment for rapid negative-pressure patient-room conversion.
  • 150–475 CFM adjustment
  • Portable floor-standing format
  • H14 final filtration
Запрос котировки Просмотреть продукты

Введение продукции

This portable unit covers small and medium isolation-room duties without permanent mounting. Its broad variable-airflow range lets staff establish the required room air balance, while the lower settings reduce sound when full 475 CFM output is unnecessary.

Основные характеристики

Rapid room conversion

The wheeled enclosure can be positioned for temporary isolation without rebuilding the room air system.

Wide airflow control

Output can be matched to room volume instead of operating continuously at peak flow.

Low-setting acoustics

Published sound spans 38–59 dBA at 1.5 m across the operating range.

Технические параметры

Airflow Range150–475 CFM
Final FilterH14 HEPA, nominal 99.995% at 0.3 µm
Sound Level38–59 dBA at 1.5 m
MountingPortable floor-standing
Operating ModesNegative-pressure exhaust or in-room filtration
Approximate Room VolumeUp to about 2500–3000 ft³ at 12 ACH, depending on configuration
Управление воздушным потокомVariable
Discharge InterfaceConfigurable filtered-air connection
Primary UseTemporary patient-room isolation
CustomizationDuct adapter, discharge route and mobility accessories can be configured for the room layout.

Applications

Emergency patient isolation, infection-control surge rooms and temporary negative-pressure conversion in hospitals or clinics.

Solutions for Your Application

A standard room must become an isolation space quickly.Position the portable unit, establish a controlled discharge path and balance airflow to the room.
Peak airflow creates unnecessary noise in a smaller room.Set output to the airflow needed for the target air-change rate rather than defaulting to 475 CFM.

Доступные варианты

Flexible ducting, window or wall discharge adapters and mobility accessories can be selected for the room.

Planning a Negative-Pressure Isolation Room Unit 475 CFM Portable specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.