Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Ana Sayfa / Ürünler / Temiz Oda Ekipmanları / Dynamic HEPA Pass Box 18 × 18 × 24 in
STJH-DYNAMIC-PASS-BOX-18X18X24

Dynamic HEPA Pass Box 18 × 18 × 24 in

A compact actively filtered transfer chamber for small particle-sensitive loads requiring interior air recovery.
  • 18 x 18 x 24 in chamber
  • Continuous HEPA recirculation
  • 25 x 36.5 in wall cutout
Alıntı isteği Browse ürünleri

Ürün tanıtımı

This wall-mounted 304 stainless pass box continuously recirculates chamber air through HEPA media. Bottom return slots draw air back to the filter, while blower speed control adjusts the recirculation duty. The 18 x 18 x 24 in work zone is intended for small aseptic components and samples, with a 25 x 36.5 in wall cutout guiding installation planning.

Ana Özellikler

Active particle recovery

Recirculation removes airborne contamination introduced during door opening instead of relying on passive settling.

Low-level air return

Slots along the chamber bottom pull air back through the filter without occupying the usable work surface.

Adjustable blower duty

Speed control lets commissioning balance airflow, pressure and noise for the installed condition.

Teknik parametreler

Inside Dimensions18 W x 18 D x 24 H in
Product Dimensions24.5 W x 18 D x 36 H in
Wall Cutout25 W x 36.5 H in
Chamber Material304 stainless steel
FiltrationRecirculating HEPA
Filter Efficiency99.99% at 0.3 µm source design
Air ReturnBottom interior slots
Motor TypeBrushless DC
Electrical Supply120 V source configuration
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Applications

For aseptic samples, electronics components and small prepared materials that benefit from active chamber cleanup. Commission airflow after installation and define a purge interval before the clean-side door releases.

Solutions for Your Application

Particles remain suspended after the less-clean-side door closes.Operate the recirculating HEPA blower for a defined recovery period before permitting clean-side access.
The filter and fan package may not fit a standard pass-through opening.Coordinate the 25 x 36.5 in cutout and service clearance before the partition is closed.

Mevcut Seçenekler

Select electronic interlock, leak-rated door, filter alarm, electropolish and alternate voltage. Determine whether filter-housing leak testing is needed for the process.

Planning a Dynamic HEPA Pass Box 18 × 18 × 24 in specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat