Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Início / Produtos / Equipamento de Cleanroom / Dynamic HEPA Pass Box 18 × 18 × 24 in
STJH-DYNAMIC-PASS-BOX-18X18X24

Dynamic HEPA Pass Box 18 × 18 × 24 in

A compact actively filtered transfer chamber for small particle-sensitive loads requiring interior air recovery.
  • 18 x 18 x 24 in chamber
  • Continuous HEPA recirculation
  • 25 x 36.5 in wall cutout
Solicite um orçamento. Browse produtos

Introdução do produto

This wall-mounted 304 stainless pass box continuously recirculates chamber air through HEPA media. Bottom return slots draw air back to the filter, while blower speed control adjusts the recirculation duty. The 18 x 18 x 24 in work zone is intended for small aseptic components and samples, with a 25 x 36.5 in wall cutout guiding installation planning.

Características-chave

Active particle recovery

Recirculation removes airborne contamination introduced during door opening instead of relying on passive settling.

Low-level air return

Slots along the chamber bottom pull air back through the filter without occupying the usable work surface.

Adjustable blower duty

Speed control lets commissioning balance airflow, pressure and noise for the installed condition.

Parâmetros técnicos

Inside Dimensions18 W x 18 D x 24 H in
Product Dimensions24.5 W x 18 D x 36 H in
Wall Cutout25 W x 36.5 H in
Chamber Material304 stainless steel
FiltrationRecirculating HEPA
Filter Efficiency99.99% at 0.3 µm source design
Air ReturnBottom interior slots
Motor TypeBrushless DC
Electrical Supply120 V source configuration
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Applications

For aseptic samples, electronics components and small prepared materials that benefit from active chamber cleanup. Commission airflow after installation and define a purge interval before the clean-side door releases.

Solutions for Your Application

Particles remain suspended after the less-clean-side door closes.Operate the recirculating HEPA blower for a defined recovery period before permitting clean-side access.
The filter and fan package may not fit a standard pass-through opening.Coordinate the 25 x 36.5 in cutout and service clearance before the partition is closed.

Opções disponíveis

Select electronic interlock, leak-rated door, filter alarm, electropolish and alternate voltage. Determine whether filter-housing leak testing is needed for the process.

Planning a Dynamic HEPA Pass Box 18 × 18 × 24 in specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato