Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Ana Sayfa / Ürünler / Cleanroom Air Filters / Antistatic HEPA Filter for Hazardous Areas 610 × 610 × 292 mm H14 V-Bank ATEX-Supported
STJH-ATEX-HEPA-H14-610X610X292

Antistatic HEPA Filter for Hazardous Areas 610 × 610 × 292 mm H14 V-Bank ATEX-Supported

A deep conductive H14 V-bank selected when hazardous-area air needs tighter final particle retention than the H13 version.
  • H14 efficiency class
  • 3400 m3/h rated duty
  • Stainless conductive housing
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The H14 version retains the 610 x 610 x 292 mm conductive metal format but changes the performance balance to 3400 m3/h at 270 Pa. It is intended for buyers whose contamination assessment requires H14 efficiency and whose fan can be commissioned at the lower rated flow. Stainless construction, a dirty-side gasket and an explicit grounding route must be coordinated with the classified-air housing rather than treated as interchangeable details.

Ana Özellikler

Higher capture grade

H14 media supports more critical final-air duty while preserving the compact V-bank footprint of the full-module cell.

Defined airflow balance

The documented 3400 m3/h and 270 Pa clean point gives the designer a concrete basis for fan and bank sizing.

Robust industrial depth

A 292 mm enclosure protects the V-arranged packs and suits side-access or built-up banks designed for deep cells.

Teknik parametreler

Dimensions610 x 610 x 292 mm
Efficiency ClassH14
Rated Airflow3400 m3/h
Initial Pressure Drop270 Pa ±10%
Frame ConstructionConductive stainless steel catalogue frame
Seal PositionDirty-side compression gasket
Maximum Operating Temperature120 C
Moisture Resistance100% RH
Fire ClassificationE d0 according to EN 13501-1
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Applications

Appropriate for classified pharmaceutical, chemical, food or combustible-dust process ventilation where H14 final filtration is part of the contamination-control design. Selection requires documented compatibility with the zone, explosive substance group, housing and bonding scheme.

Solutions for Your Application

The specification calls for H14, but the schedule still assumes the H13 airflow.Size this cell at its 3400 m3/h rated point and rebalance the bank instead of carrying over the 4000 m3/h H13 value.
Static continuity can be lost across painted or poorly clamped rack surfaces.Use deliberate conductive contact points and verify continuity from every installed frame to the system earth.

Mevcut Seçenekler

Define the exact ATEX zone and group, airflow orientation, gasket face, rack earthing detail and access clearance for the 292 mm cell.

Planning a Antistatic HEPA Filter for Hazardous Areas 610 × 610 × 292 mm H14 V-Bank ATEX-Supported specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim