STJH-ATEX-HEPA-H14-610X610X292

Antistatic HEPA Filter for Hazardous Areas 610 × 610 × 292 mm H14 V-Bank ATEX-Supported

A deep conductive H14 V-bank selected when hazardous-area air needs tighter final particle retention than the H13 version.
  • H14 efficiency class
  • 3400 m3/h rated duty
  • Stainless conductive housing
Запрос котировки Просмотреть продукты

Введение продукции

The H14 version retains the 610 x 610 x 292 mm conductive metal format but changes the performance balance to 3400 m3/h at 270 Pa. It is intended for buyers whose contamination assessment requires H14 efficiency and whose fan can be commissioned at the lower rated flow. Stainless construction, a dirty-side gasket and an explicit grounding route must be coordinated with the classified-air housing rather than treated as interchangeable details.

Основные характеристики

Higher capture grade

H14 media supports more critical final-air duty while preserving the compact V-bank footprint of the full-module cell.

Defined airflow balance

The documented 3400 m3/h and 270 Pa clean point gives the designer a concrete basis for fan and bank sizing.

Robust industrial depth

A 292 mm enclosure protects the V-arranged packs and suits side-access or built-up banks designed for deep cells.

Технические параметры

Dimensions610 x 610 x 292 mm
Efficiency ClassH14
Rated Airflow3400 m3/h
Initial Pressure Drop270 Pa ±10%
Frame ConstructionConductive stainless steel catalogue frame
Seal PositionDirty-side compression gasket
Maximum Operating Temperature120 C
Moisture Resistance100% RH
Fire ClassificationE d0 according to EN 13501-1
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Applications

Appropriate for classified pharmaceutical, chemical, food or combustible-dust process ventilation where H14 final filtration is part of the contamination-control design. Selection requires documented compatibility with the zone, explosive substance group, housing and bonding scheme.

Solutions for Your Application

The specification calls for H14, but the schedule still assumes the H13 airflow.Size this cell at its 3400 m3/h rated point and rebalance the bank instead of carrying over the 4000 m3/h H13 value.
Static continuity can be lost across painted or poorly clamped rack surfaces.Use deliberate conductive contact points and verify continuity from every installed frame to the system earth.

Доступные варианты

Define the exact ATEX zone and group, airflow orientation, gasket face, rack earthing detail and access clearance for the 292 mm cell.

Planning a Antistatic HEPA Filter for Hazardous Areas 610 × 610 × 292 mm H14 V-Bank ATEX-Supported specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.