ผู้จัดจําหน่ายแบบครบวงจรสําหรับอุปกรณ์ห้องคลีนรูมและสิ่งจําเป็นสําหรับสิ่งอํานวยความสะดวกปลอดเชื้อการสนับสนุนโครงการระหว่างประเทศ
Open mobile navigationClose mobile navigation
หน้าแรก / ผลิตภัณฑ์ / Cleanroom HVAC Systems / Finned-Tubular Electric Air Heater 30 kW Fan-Forced
STJH-FINNED-TUBULAR-ELECTRIC-AIR-HEATER-30KW

Finned-Tubular Electric Air Heater 30 kW Fan-Forced

A high-output 30 kW fan-forced heater with 38 A total current and an approximate 79 F discharge-air temperature rise.
  • 30 kW heating output
  • 38 A total current
  • Approximately 79 F air rise
ขอใบเสนอราคา เรียกดูสินค้า

การแนะนําสินค้า

This largest fixed assembly doubles the medium heater's output to 30 kW while using a larger fan-forced housing. The documented 38 A current and approximately 79 F temperature rise suit high-heat-loss clean utility and mechanical support areas.

คุณสมบัติที่สําคัญ

High support-space output

The large element bank addresses substantial ventilation or envelope heat loss.

Concentrated warm-air delivery

The fan-forced cabinet projects heat into a larger utility area rather than relying on passive convection.

Heavy electrical duty

The published 38 A load makes power and protective coordination explicit for the high-capacity assembly.

พารามิเตอร์ทางเทคนิค

Heating Capacity30 kW
Power Supply480 V, three phase
Total Current38 A
Fan Motor1/4 hp
Approximate Air Rise79 F / 44 C
ElementsStainless finned tubular
Air DeliveryLarge fan-forced housing
Safety ControlHigh-limit and fan interlock options
InstallationLarge utility or mechanical support area
การปรับแต่งHeating stages, control voltage and mounting arrangement can be configured for the intended application and operating environment.

Applications

Large clean utility rooms, high-heat-loss mechanical spaces, process-support areas and equipment freeze protection.

Solutions for Your Application

The medium heater cannot recover room temperature after a large door opening or ventilation event.Use the 30 kW output with staged or thermostatic control matched to the calculated heat loss.
The high discharge-temperature rise could overheat nearby materials.Maintain manufacturer-based clearance and aim the fan discharge into an open circulation path.

ตัวเลือกที่มีอยู่

Staged heat, thermostat, remote control, disconnect, fan delay, high-limit controls, mounting hardware and enclosure finish can be selected.

Planning a Finned-Tubular Electric Air Heater 30 kW Fan-Forced specification?

ส่งมิติของคุณเงื่อนไขการติดตั้งเป้าหมายประสิทธิภาพและผิวที่ต้องการ

พูดคุยกับทีมงานของเรา
อีเมลถึงเรา WhatsApp WeChat