Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Inicio / Productos / Cleanroom Air Filters / Permanganate-Impregnated Media Filter 610 × 152 × 457 mm Low-Drop
STJH-PERMANGANATE-MEDIA-FILTER-610X152X457

Permanganate-Impregnated Media Filter 610 × 152 × 457 mm Low-Drop

A narrow half-cubic-foot cassette designed to add permanganate gas treatment where fan static is limited.
  • 101 Pa maximum drop
  • One-inch media bed
  • 0.5 ft3 media charge
Solicite un presupuesto. Browse productos

Introducción del producto

The 610 x 152 x 457 mm format reorients the chemical bed into a narrow six-inch-high cassette. Its one-inch media path and 0.5 ft3 charge hold the maximum published resistance to 101 Pa at 2.54 m/s, trading some total capacity for easier integration into constrained air handlers. It is most useful when molecular filtration must be retrofitted without the pressure demand of the deeper 305 mm module.

Características clave

Static-pressure economy

The shallow bed reduces airflow resistance relative to the three-inch packed module.

Narrow cassette profile

A 152 mm module height supports retrofit arrangements that cannot accept a 305 mm face.

Serviceable chemical stage

The factory-filled cassette can be exchanged as a complete unit without loose-media transfer at the rack.

Parámetros técnicos

Nominal Dimensions610 x 152 x 457 mm
Media Volume0.5 ft3
Packed Bed Depth1 in
Maximum Pressure Drop101 Pa at 2.54 m/s
Media TypePermanganate-impregnated engineered media blend
ConstructionDisposable sealed module
Reference Face Velocity2.54 m/s
Primary AdvantageReduced molecular-stage resistance
InstallationNarrow gas-phase cassette rack
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Applications

Fits gas-phase retrofits, compact AHUs and cleanroom support systems that need corrosion or odor control but have restricted fan static and rack height.

Solutions for Your Application

Reducing bed depth causes the media to reach breakthrough too soon.Estimate chemical load against the 0.5 ft3 charge and increase parallel modules or service frequency when capacity is insufficient.
A retrofit rack bypasses air around the narrow cassette.Use continuous perimeter seals and blanking plates so the measured airflow passes through the chemical bed.

Opciones disponibles

Select media chemistry, module quantity, gasket arrangement, access side, prefilter, gas monitoring and maintenance interval from site conditions.

Planning a Permanganate-Impregnated Media Filter 610 × 152 × 457 mm Low-Drop specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto