Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Inicio / Productos / Equipos de sala limpia / Fan Filter Unit 24 × 36 in Low-Profile
STJH-LOW-PROFILE-FFU-24X36-318MM

Fan Filter Unit 24 × 36 in Low-Profile

A three-foot low-profile FFU that adds clean-air coverage without increasing cabinet height.
  • 600 x 905 mm rectangular footprint
  • 693 CFM maximum airflow
  • 42 lb intermediate-size assembly
Solicite un presupuesto. Browse productos

Introducción del producto

The 24 x 36 in model extends the active filter area to 5.3 ft² while retaining the same 12.375 in shallow cabinet used across the series. It reaches a published maximum airflow of 693 CFM and produces 470 CFM at a 90 FPM reference face velocity. This intermediate proportion is suited to process lanes that outgrow a square module but do not require the full length, weight or sound output of the 24 x 48 in version.

Características clave

Three-foot filter face

The extended 36 in side covers a longer workstation zone while preserving a manageable two-foot width.

Shallow family depth

A constant 318 mm cabinet height supports installation below low decks without sacrificing the larger face area.

Balanced middle duty

Its 470 CFM reference output and 64 dBA published sound point sit between the compact and full-length configurations.

Parámetros técnicos

Nominal Module Size2 x 3 ft
External Dimensions23.63 x 35.63 x 12.375 in (600 x 905 x 318 mm)
Active Filter Area5.3 ft²
Maximum Airflow693 CFM
Reference Airflow470 CFM at 90 FPM
Maximum-Airflow Power190 W
Reference Sound Level64 dBA at 90 FPM
Unit Weight42 lb
InstallationSupported rectangular ceiling-grid mounting
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Applications

Designed for pharmaceutical support rooms, precision assembly lines and inspection bays under low roof decks. The 905 mm axis should follow the process length, with adequate long-side support and sufficient return-air capacity for the selected operating point.

Solutions for Your Application

A square FFU leaves the ends of a medium process zone outside the primary supply area.Orient the 905 mm side over the work path to extend the filtered-air footprint along the process.
The longer cabinet may load a light ceiling rail unevenly.Provide rated support along both long edges and verify the frame for the 42 lb unit before installation.

Opciones disponibles

Select the final filter, supply voltage, speed controller and sealing method for the project. Ceiling support and service clearance should be coordinated around the 600 x 905 mm footprint.

Planning a Fan Filter Unit 24 × 36 in Low-Profile specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto