Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Inicio / Productos / Equipos de sala limpia / STJH 610 x 610 mm High-Flow EC Fan Filter Unit
STJH-EC-FAN-FILTER-UNIT-610X610-10CMM

STJH 610 x 610 mm High-Flow EC Fan Filter Unit

The highest-flow square format in this three-model group, intended for larger equipment enclosures.
  • 610 mm square filter module
  • Approximately 10 m³/min airflow
  • Approximately 65 W unit power consumption
Solicite un presupuesto. Browse productos

Introducción del producto

A 610 mm square module and higher-output brushless fan distinguish this unit from the 400 and 500 mm versions. Overall height remains 185 mm including the intake guard, while nominal delivery rises to approximately 10 m³/min. This format suits a wider roof opening and needs a return-air path sized for the increased flow.

Características clave

Six-point mounting layout

Six perimeter mounting slots distribute support around the wider module when it is fixed to a suitable enclosure frame.

Serviceable inlet arrangement

The protected top inlet remains accessible for inspection when maintenance clearance is reserved above the enclosure.

Independent speed setting

Local adjustment allows the module output to be balanced against the enclosure opening and return resistance.

Parámetros técnicos

Nominal Module Dimensions610 × 610 mm mounting footprint; 185 mm overall height including intake guard, excluding cable and service clearance
Nominal AirflowApproximately 10 m³/min
Average Outlet VelocityApproximately 0.51 m/s
Final FilterHEPA; filtration configuration rated at least 99.99% at 0.3 µm
Housing MaterialSUS430 stainless steel, bright annealed finish
Fan and ControlOne brushless DC fan with variable-speed control
Power SupplyAC 100 V, single phase, 50/60 Hz
Nominal Power ConsumptionApproximately 65 W
Approximate Weight12 kg
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Applications

Intended for larger precision-process covers, instrument enclosures and electronics work cells. Supporting structures must carry the unit independently; the filter face is not a load-bearing surface. Installed cleanliness depends on the complete enclosure and operating conditions.

Customer Product Concerns and Solutions

A larger enclosure needs more replacement air than the smaller modules can supply.Use the 10 m³/min reference duty to assess demand, then balance the installed flow against leakage and return resistance.
Higher airflow causes excessive turbulence around the process.Adjust fan speed and provide adequate return area; check the working zone rather than relying on the maximum setting.

Opciones disponibles

Discuss the return-air layout, mounting details, final-filter requirement and electrical supply for the larger enclosure. Any alternative arrangement must be matched to the actual process before ordering.

Planning a STJH 610 x 610 mm High-Flow EC Fan Filter Unit specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat