STJH-AIR-TO-AIR-PLATE-HEAT-RECOVERY-1200MM

Air-to-Air Plate Heat Recovery Unit 1200 mm

The largest single plate core for high-volume separated-stream recovery with no moving parts.
  • 1200 mm large plate
  • Approximately 1697 mm profile envelope
  • 1500-1700 Pa tight-gap differential
Solicite un presupuesto. Browse productos

Introducción del producto

This H2 core uses 1200 mm plates and module widths from 350-1200 mm. Its 90-degree profile envelope is approximately 1697 mm, making it physically distinct from the two smaller units. At 2.0-3.0 mm spacing, documented maximum differential-pressure capability is 1500-1700 Pa depending on the exact build. The large passive core suits central facilities but requires careful transport, casing support and frost management.

Características clave

Large single-core capacity

The 1200 mm diagonal handles central AHU flow without assembling many small exchangers.

High differential option

Tighter-gap constructions provide documented structural pressure capability for separated streams.

Passive operation

No wheel motor, belt or pumped loop is required for sensible heat transfer.

Parámetros técnicos

Plate Size1200 mm
Module Width350-1200 mm
Profile EnvelopeApproximately 1697 mm at 90-degree profile
Plate Spacing2.0-6.0 mm by selection
Maximum Differential Pressure1500-1700 Pa at 2.0-3.0 mm spacing
Plate MaterialAluminum
Flow ArrangementCrossflow
Moving PartsNone
Primary DutyLarge central air-to-air recovery
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Applications

For large clean-facility air handlers requiring separated supply and exhaust sensible heat recovery without rotating components.

Solutions for Your Application

The 1697 mm envelope cannot pass through the plant access route.Coordinate external casing, lifting path and sectional delivery before manufacture.
A large frosted core blocks exhaust airflow during cold weather.Use bypass, preheat, face-and-bypass or defrost control based on the actual psychrometric frost point.

Opciones disponibles

Confirm airflow, profile angle, width, spacing, pressure differential, seal, casing, bypass, drainage, frost protection and lifting.

Planning a Air-to-Air Plate Heat Recovery Unit 1200 mm specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.