Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
Главная / Продукция / Cleanroom Air Filters / ePTFE Membrane HEPA Filter H14 Gel-Seal
STJH-EPTFE-HEPA-H14-GEL

ePTFE Membrane HEPA Filter H14 Gel-Seal

A robust H14 membrane panel with a filter-mounted gel trough for aseptic bottom-load terminals.
  • Filter-mounted gel trough
  • H14 supported membrane
  • Bottom-load terminal interface
Запрос котировки Просмотреть продукты

Введение продукции

The gel-seal ePTFE model places a continuous fluid channel in the anodized aluminum perimeter. A housing knife edge enters the gel when the panel is raised into a bottom-load terminal, while the supported membrane provides H14 efficiency, low outgassing and high tensile strength. This arrangement is distinct from the gasket model because sealing depends on knife-edge immersion rather than clamp compression.

Основные характеристики

Low-bypass fluid path

The continuous gel channel conforms around the mating knife edge and can reveal discontinuities through its impression.

Maintenance-tolerant media

Supported ePTFE reduces the risk of incidental handling damage during room-side replacement.

Aseptic service geometry

The bottom-load format allows filter changeout without opening a common plenum above the room.

Технические параметры

HEPA ClassH14 / at least 99.995% at MPPS
Filter MediumSupported ePTFE membrane
Perimeter FrameAnodized aluminum
Seal ConfigurationIntegral low-outgassing gel channel
Mating ComponentKnife edge on terminal housing
Media CharacteristicsLow pressure drop and high tensile strength
Environmental PropertyHydrophobic membrane surface
Access ModeRoom-side or bottom-load replacement
Service CheckInspect gel surface and knife-edge impression
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Applications

Selected for aseptic pharmaceutical terminals, biotechnology rooms and controlled filling areas with a housing knife edge and room-side access. It is useful when a fluid seal and durable membrane media are both required, provided gel chemistry is compatible with the sanitation program.

Solutions for Your Application

Filter replacement above an aseptic room would disturb inaccessible plenum services.The gel-channel panel supports bottom-load changeout from the controlled room when paired with a compatible terminal.
Old gel residue prevents complete knife-edge immersion.Remove approved residue from the housing edge, inspect the new channel and insert the filter vertically without dragging.

Доступные варианты

Choose gel material, channel dimensions, exact frame size, upstream screen and room-side retaining hardware for the terminal.

Planning a ePTFE Membrane HEPA Filter H14 Gel-Seal specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.