A thin novolac epoxy ESD system for chemical-handling areas where ordinary static-control epoxy is not the preferred resin.
  • Conductive novolac epoxy wearing layer
  • 0.6-0.8 mm total system
  • Smooth finish with grounded primer architecture
Запрос котировки Просмотреть продукты

About This Product

NOVOLAC-08 uses a conductive novolac epoxy wearing coat over a conductive primer and prepared epoxy-primed base. The complete construction is approximately 0.6-0.8 mm, distinct from the thickness of the individual wearing coat. Novolac chemistry provides the chemical-resistance basis, while the grounding and footwear arrangement provides the static-control system. It is a smooth coating rather than a thick chemical-resistant broadcast floor.

Основные характеристики

Dual selection criteria

Resin choice addresses the expected chemical exposure, while the conductive construction addresses static charge generated in the working area.

Through-layer conductivity

The conductive wearing material forms part of the charge path throughout its thickness, rather than relying on a temporary surface treatment.

Compact smooth body

The shallow unbroadcast build can suit sound existing floors where additional screed depth would interfere with equipment clearances.

Технические параметры

Resin TypeTwo-component novolac epoxy
Total Build0.6-0.8 mm
UnderlayersEpoxy primer and conductive primer
SurfaceSmooth nonporous coating
Electrical ConstructionThrough-thickness conductive wearing layer
Reference Conductive Range2.5 × 10⁴ to 1.0 × 10⁶ Ω
Footwear ArrangementCompatible ESD footwear
Ground ConnectionVia conductive underlayer
Chemical DutySelected chemical splash and spill exposure
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Applications

Appropriate for chemical-handling electronics rooms and pharmaceutical process support areas. Chemical identity, concentration and contact duration matter when selecting the resin package. The floor and ESD footwear should be considered together instead of treating a resistance value as a complete protection system.

Solutions for Your Application

The floor must handle chemical exposure as well as static-sensitive work.

Select the novolac wearing resin with the complete grounded ESD layer arrangement.

A standard novolac coating is assumed to provide ESD control.

Specify the conductive formulation and primer explicitly; the resin name alone does not establish static-control behaviour.

Доступные варианты

Choose colour, compatible cove and earthing configuration. Maintain the smooth unbroadcast architecture and discuss the actual chemical exposure so surface selection remains specific to the room.