Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Início / Produtos / Cleanroom Air Filters / Safe-Change Filter Housing Stainless Gasket-Seal
STJH-SAFE-CHANGE-HOUSING-SS-GASKET

Safe-Change Filter Housing Stainless Gasket-Seal

A welded stainless safe-change cabinet for corrosive or frequently cleaned containment ventilation.
  • 304 or 316 stainless options
  • Up to ±15 in. w.g. family duty
  • Horizontal or vertical flow
Solicite um orçamento. Browse produtos

Introdução do produto

This safe-change housing uses 11- or 14-gauge 304 or 316 stainless steel around a gasket-seal HEPA or molecular filter. The stronger corrosion resistance and published pressure capability of up to plus or minus 15 in. w.g. distinguish it from the painted-steel version. Horizontal and vertical arrangements are possible, but the selected door, bagging ring and clamping mechanism must remain accessible in the installed orientation.

Características-chave

Corrosion-resistant pressure boundary

Welded stainless construction suits washdown, humid and chemically demanding exhaust better than coated carbon steel.

Gasket filter versatility

The clamping frame can be configured for particulate HEPA or molecular filter stages with the required gasket position.

Orientation flexibility

Cabinet sections can be arranged for horizontal, upflow or downflow service when access is coordinated.

Parâmetros técnicos

Housing Material11- or 14-gauge 304 or 316 stainless steel
Filter TypeGasket-seal HEPA or molecular filter
Filter SealMechanical gasket compression
Change MethodBag-in/bag-out
Family Pressure CapabilityUp to ±15 in. w.g.
Flow OrientationHorizontal or vertical
Cabinet ConstructionFully welded
AccessSide service with bagging ring
Superfície acabadoStainless mill or cleaned finish by selection
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Applications

For pharmaceutical, chemical, high-containment laboratory and critical industrial exhaust where stainless construction and controlled filter replacement are required.

Solutions for Your Application

The selected stainless grade pits in the actual disinfectant or process exhaust.Review chloride, acid and cleaning exposure before choosing 304 or 316 and specify the appropriate weld finishing.
Vertical installation leaves insufficient room to manipulate the change bag safely.Coordinate the service platform, bag extension volume and filter support method for the final airflow orientation.

Opções disponíveis

Specify stainless grade, material gauge, weld finish, filter type and depth, gasket location, test ports, bagging system and airflow direction.

Planning a Safe-Change Filter Housing Stainless Gasket-Seal specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato