Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Início / Produtos / Equipamento de Cleanroom / Fan Filter Unit 24 × 36 in High-Airflow
STJH-HIGH-AIRFLOW-FFU-24X36-650CFM

Fan Filter Unit 24 × 36 in High-Airflow

A medium rectangular high-flow FFU sized between compact square and full-length ceiling modules.
  • 160-650 CFM airflow range
  • 600 x 905 x 364 mm cabinet
  • 47 dBA at 90 FPM
Solicite um orçamento. Browse produtos

Introdução do produto

The 24 x 36 in high-airflow FFU supplies from 160 to 650 CFM through a 600 x 905 mm cabinet. At the 90 FPM reference point, it provides 470 CFM with a cited 47 dBA sound level. Its 364 mm depth and 52 lb weight make it a lighter, shorter alternative to the 24 x 48 in model while still extending supply coverage along one axis.

Características-chave

Intermediate high-flow footprint

The three-foot length expands coverage beyond a square module without the span and weight of the largest format.

ECM airflow adjustment

The electronically commutated motor supports balancing across the published 160-650 CFM operating range.

Quiet reference duty

The listed 47 dBA value at 90 FPM supports use near occupied assembly and inspection zones.

Parâmetros técnicos

Nominal Module Size2 x 3 ft
External Dimensions600 x 905 x 364 mm
Airflow Range160-650 CFM
Reference Airflow470 CFM at 90 FPM
Maximum-Airflow Power150 W
Reference Sound Level47 dBA at 90 FPM
Motor TypeECM
Unit Weight52 lb
InstallationSupported rectangular cleanroom ceiling mounting
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Applications

Designed for medium cleanroom bays, equipment canopies and assembly zones that need more filtered-air coverage than a 2 x 2 ft module. The 905 mm axis can follow the process direction while avoiding the support demands of a full 1200 mm housing.

Solutions for Your Application

A compact square unit cannot cover the full width of a medium tool.Align the three-foot side with the longer process dimension and balance the ECM for the required outlet velocity.
A 2 x 4 ft module would add unnecessary weight and ceiling span.Use the 52 lb 2 x 3 ft configuration where 650 CFM is sufficient for the verified room duty.

Opções disponíveis

Select the final filter, supply voltage, ECM control method, housing finish and ceiling seal. Verify the chosen airflow against room pressure, filter resistance and return-air capacity.

Planning a Fan Filter Unit 24 × 36 in High-Airflow specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato