STJH-FFU-BMS-GATEWAY-MODBUS-TCP

FFU BMS Gateway Modbus RTU-to-TCP

A transparent RS485-to-Ethernet bridge for connecting Modbus RTU FFUs to a Modbus TCP supervisor.
  • Modbus RTU field protocol
  • Modbus TCP BMS protocol
  • RS485-to-Ethernet bridge
Solicite um orçamento. Browse produtos

Introdução do produto

This gateway connects a field network of Modbus RTU fan filter units to a Modbus TCP building supervisor. It translates the physical path from RS485 to Ethernet while preserving the Modbus data model. The product is selected when the FFU layer already uses RTU and the facility BMS expects TCP rather than BACnet or an IoT protocol.

Características-chave

Protocol continuity

Both sides use Modbus, reducing semantic translation between fan data and the supervisor.

Physical-layer conversion

RS485 fan wiring is exposed through an Ethernet connection.

FFU-focused integration

The gateway links speed, status and alarm points to the facility network.

Parâmetros técnicos

Field ProtocolModbus RTU
BMS ProtocolModbus TCP
Field Physical LayerRS485
Upstream ConnectionEthernet
Z AplicaçãoFFU network integration
Data DirectionBidirectional commands and status
Address MappingConfigured to fan network addresses
InstallationControl enclosure or network panel
Supervisory SystemModbus TCP client
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Applications

Suitable for facilities whose BMS uses Modbus TCP while ceiling fans communicate over RTU. Registers, unit addresses and network security should be documented before integration.

Solutions for Your Application

The BMS Ethernet interface cannot connect directly to RS485 fans.Use the gateway to bridge Modbus RTU to Modbus TCP.
Unplanned register mapping causes incorrect commands.Freeze the point list and address map before BMS testing.

Opções disponíveis

Specify RS485 segment count, Ethernet settings, address map, enclosure and power supply. Confirm the BMS acts as a compatible Modbus TCP client.