Laman Utama / Produk / Peralatan Bilik Bersih / Active Cleanroom Material Airlock 500 mm
STJH-MATERIAL-AIRLOCK-500-ACTIVE

Active Cleanroom Material Airlock 500 mm

A compact self-ventilated material lock for small sealed components crossing adjacent clean zones.
  • 500 mm cubic interior
  • Integral blower and H14 HEPA
  • Autonomous vertical displacement flow
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The smallest active model provides a 500 mm cubic transfer space within a 700 x 575 x 1000 mm body. Its own blower and H14 HEPA filter create autonomous vertical low-turbulence displacement airflow, independent of the room duct system. A stainless housing, base and installation frame support wall integration where small tools or containers need an actively swept transfer chamber.

Ciri-ciri Utama

Compact active protection

The 500 mm chamber adds filtered purge capability without the footprint of the larger material-lock models.

Independent air supply

An integral blower lets the chamber operate without supply and exhaust connections to the central cleanroom HVAC.

Hygienic wall integration

A V2A stainless housing, base and installation frame provide cleanable surfaces around the transfer opening.

Parameter teknikal

Internal Dimensions500 W x 500 D x 500 H mm
External Dimensions700 W x 575 D x 1000 H mm
Housing MaterialV2A stainless steel 1.4301
Final FilterH14 HEPA
AirflowVertical low-turbulence displacement flow
BlowerIntegral autonomous fan
Door OperationOne-door-at-a-time interlock
InstallationWall-integrated with base and frame
Typical LoadSmall containers, tools and components
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Applications

For small containers, tools and sealed component packs transferred between pharmaceutical or medical-device clean zones. The surrounding room classifications and pressure cascade determine the operating cleanliness achieved by the chamber.

Solutions for Your Application

A passive hatch does not actively sweep particles from the load space.Use the integral blower and H14 filter to establish vertical displacement airflow during the transfer cycle.
Central duct connections are unavailable at the selected wall.Choose the autonomous active model, which does not depend on the room ventilation branch.

Pilihan yang boleh didapati

Available options include corner door positioning, horizontal flow, trolley arrangement, wall console and emergency stop. Dimensions and control timing can be adapted to the load and partition.

Planning a Active Cleanroom Material Airlock 500 mm specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat