Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Laman Utama / Produk / Cleanroom HVAC Systems / Heat-Pipe Energy Recovery Unit Over-Under Single-Season
STJH-HEAT-PIPE-ENERGY-RECOVERY-OVERUNDER

Heat-Pipe Energy Recovery Unit Over-Under Single-Season

A stacked-air-stream thermosiphon that transfers heat strongly in one selected seasonal direction.
  • Over-under air paths
  • Passive vertical thermosiphon
  • Single-season recovery bias
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

This heat-pipe unit places one air stream above the other and uses vertical 1/2 in copper tubes as a passive thermosiphon. Gravity-assisted liquid return creates strong transfer in one selected direction, so the circuit is optimized for either a dominant heating or cooling season rather than equal bidirectional duty. The stacked housing is especially suitable where supply and exhaust ducts already run over and under each other.

Ciri-ciri Utama

Gravity-assisted circulation

Vertical tubes return condensed working fluid to the evaporator without a mechanical pump.

Stacked duct integration

One coil face sits in each over-under air stream across a sealed partition.

Strong one-way recovery

Orientation is selected around the dominant annual heating or cooling benefit.

Parameter teknikal

Air-Stream ArrangementOver-under
Recovery BiasSingle-season one-way
Tube Outside Diameter1/2 in copper
OperationPassive thermosiphon
Tube OrientationVertical
Air SeparationSealed stacked partition
Energy TransferSensible
Moving PartsNone
Primary DutyDominant heating or cooling season
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Applications

For clean facilities with stacked ducts and a dominant heating or cooling season requiring separated-stream passive recovery.

Solutions for Your Application

The thermosiphon is selected for the wrong seasonal heat-flow direction.Define the dominant recovery mode and place the evaporator below the condenser for that condition.
Field tilt or casing settlement disrupts gravity return.Provide level structural support and verify vertical tube orientation during commissioning.

Pilihan yang boleh didapati

Specify dominant season, supply and exhaust positions, rows, fin density, casing, coatings, partition, bypass and freeze protection.

Planning a Heat-Pipe Energy Recovery Unit Over-Under Single-Season specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami