An intermediate-width carbon V-bank for 490 mm rack positions, balancing higher airflow with a compact 300 mm depth.
  • 2800 m3/h rated flow
  • 490 mm intermediate width
  • ISO 10121 molecular platform
견적 요청 제품 찾아보기

상품 소개

Built for five-sixths-width filter banks, this 592 x 490 x 300 mm molecular cartridge raises documented airflow to 2800 m3/h without increasing the 80 Pa clean resistance used across the size family. Pleated adsorbent media in a molded frame gives more working face area than the 287 mm version while avoiding the width of a 592 mm square cell. Selection begins with the gases present; particle efficiency, useful adsorbent life and downstream HEPA protection remain separate engineering decisions.

주요 기능

Intermediate module geometry

The 490 mm width matches common non-square AHU rows and helps fill legacy banks without blanking plates or a full-width redesign.

Higher flow at controlled resistance

The expanded face supports 2800 m3/h at 80 Pa, offering substantially more air capacity than the half-module option for the same depth.

Mixed-pollutant adsorbent

Broad-spectrum activated carbon addresses low-level ozone, NO2, SO2 and toluene-type VOC challenges in supply or recirculated air.

기술 매개변수

Dimensions592 x 490 x 300 mm
Rated Airflow2800 m3/h
Initial Pressure Drop80 Pa
Molecular MediaBroad-spectrum activated carbon
Target ContaminantsOzone, NO2, SO2 and toluene-type VOCs
Frame ConstructionMolded plastic V-bank
Classification BasisISO 10121-3 molecular-filter family
Maximum Operating Temperature40 C
Maximum Relative Humidity70% RH
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

Applications

Designed for medium-width make-up-air or recirculation sections in semiconductor support areas, medical buildings and pollution-exposed clean processes. Install upstream particulate filtration when dust could mask the adsorbent surface, and determine media life from the site gas profile.

Solutions for Your Application

A 490 mm legacy track leaves uncertain sealing and bypass risk around a replacement filter.Match the exact 592 x 490 mm face, confirm gasket compression over the whole header and close any rack gaps before startup.
The selected carbon may remove odors but perform poorly against the process-critical gas.Identify the priority gases and humidity first, then select the adsorbent formulation for those compounds instead of relying on a generic odor specification.

사용 가능한 옵션

Confirm carbon grade, challenge gases, expected concentration, rack orientation, access side, gasket position, upstream prefilter and sampling or monitoring method.

Planning a V-Bank Activated Carbon Filter 592 × 490 mm specification?