클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
/ 제품 / 클린룸 장비 / Fan Filter Unit 514 × 520 mm 24 VDC Low-Voltage
STJH-LOW-VOLTAGE-DC-FFU-514X520-24V

Fan Filter Unit 514 × 520 mm 24 VDC Low-Voltage

A broad-face 24 VDC HEPA supply module for covered transfer sections and larger local clean-air zones.
  • Broad-face HEPA supply module
  • 480 mm square outlet
  • Covered transfer sections
견적 요청 제품 찾아보기

상품 소개

This format uses a 450 mm square filter element beneath the fan chamber, giving the series its widest discharge face. A 150 mm-high body keeps the assembly shallow relative to its span. The 514 x 520 mm nominal size refers to a casing measuring 514 x 519.5 mm, with space also needed around its electrical connection.

주요 기능

480 mm square outlet

The 480 mm square outlet spreads supply air across a broader opening.

Five fan positions

Five fan positions let the operator reduce output when the full transfer zone is not in use.

Four mounting points

Four mounting points support integration over a hood without relying on the filter frame to carry the assembly.

기술 매개변수

Casing Dimensions514 W x 519.5 D x 150 H mm
Power Supply24 VDC
Motor TypeBrushless DC motor
Airflow SettingsFive steps: approximately 5.3 / 4.5 / 3.3 / 2.2 / 1.1 m³/min
Nominal Discharge VelocityApproximately 0.46 / 0.39 / 0.29 / 0.19 / 0.10 m/s in descending airflow order
Power ConsumptionApproximately 48 / 35 / 23 / 15 / 8 W across the five positions
Main FilterHEPA, 450 x 450 x 50 mm; nominal particle collection efficiency at least 99.99% at 0.3 µm
PrefilterAccessible mesh screen upstream of the fan
Casing MaterialAntistatic ABS housing
사용자 정의Hood attachment and power-lead routing can be configured for the intended transfer process and operating environment.

Applications

Clean-air supply above a covered conveyor transfer point. A wider local canopy for exposed component trays between process steps.

Solutions for Your Application

A narrow air outlet may leave the edges of a broad tray outside the supplied area.Position the wider outlet over the exposed region and assess edge airflow with the intended tray and hood geometry.
Increasing fan output alone can create excessive local air speed.Use the larger discharge area to distribute the flow, then select a fan position appropriate to the uncovered product and nearby openings.

사용 가능한 옵션

A higher-efficiency ULPA filter selection for sensitive transfer processes. A suitable 24 VDC connection cable for integration with machine wiring.

Planning a Fan Filter Unit 514 × 520 mm 24 VDC Low-Voltage specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat

제품

뉴스

회사 소개

문의하기