클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
/ 제품 / Cleanroom Air Filters / Low-Boron HEPA Filter 24 × 24 in H14 Gel-Seal
STJH-LOW-BORON-HEPA-H14-GEL-24X24

Low-Boron HEPA Filter 24 × 24 in H14 Gel-Seal

A 24-inch low-boron H14 separatorless panel with a fluid seal for bottom-load terminals.
  • Low-boron H14 media
  • 24-inch gel-seal frame
  • 350 cfm unidirectional duty
견적 요청 제품 찾아보기

상품 소개

The gel-seal 24 x 24 in model retains low-boron separatorless microglass media but changes the perimeter interface to an integral fluid channel. Its 350 cfm family duty supports unidirectional microelectronics supply while the gel mates with a terminal knife edge for bottom-load replacement. This version is selected when both boron control and a fluid bypass seal are required.

주요 기능

Combined contamination controls

Low-boron media addresses process chemistry while the gel path manages bypass at the housing interface.

Bottom-load service

The filter-mounted gel trough suits terminals designed for replacement from below the cleanroom ceiling.

Foreign-material reduction

Separatorless pleats avoid independent spacer strips within the outgoing clean-air stream.

기술 매개변수

Nominal Dimensions24 x 24 in face
HEPA GradeH14 / 99.995% at MPPS
Filter MediumLow-boron separatorless microglass
Family Airflow350 cfm at 100 fpm net face velocity
Perimeter SealIntegral gel channel
Mating InterfaceKnife edge on bottom-load housing
Pleat ConstructionSelf-separating, without spacer strings or strips
Target ProcessMicroelectronics with boron-source controls
MaintenanceInspect gel track and clean mating edge at changeout
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

Applications

Used in bottom-load semiconductor cleanroom terminals and other microelectronics zones that call for low-boron H14 filtration. It is the fluid-seal alternative to the 24-inch gasket model and requires a terminal-mounted knife edge matched to the gel channel.

Solutions for Your Application

The process needs low-boron media but the ceiling terminal has no gasket clamping land.Use the gel-seal frame so the terminal knife edge can engage a continuous fluid channel.
Gel contamination introduces particles during a room-side filter change.Keep the channel covered until installation and clean the housing edge with an approved method before engagement.

사용 가능한 옵션

Confirm gel material, trough position, actual 24-inch frame dimensions, screen face and microelectronics material-control requirements.

Planning a Low-Boron HEPA Filter 24 × 24 in H14 Gel-Seal specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat