클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
홈 / 제품 / 클린룸 장비 / Multi-Person Cleanroom Air Shower
인력 및 재료 오염 제거 장비

클린룸 공기 샤워기

An extended personnel air shower for organized group entry, with the chamber layout, jet zones and batch sequence selected together.
  • Group Entry Layout
  • Extended Nozzle Zones
  • Selectable Chamber Length
  • Batch Sequence Control
견적 요청 제품 찾아보기

상품 소개

The multi-person air shower extends the controlled entry stage to accommodate a group rather than an individual arrival. Nozzle panels and return sections are distributed through the enlarged chamber, while service bays contain the selected fan and filtration package. The enclosure can be divided into transportable sections when building access requires it. Chamber geometry, occupied positions and door operation are selected around the intended shift-entry routine.

주요 기능

Extended occupied zone

A longer or differently proportioned chamber can organize several standing positions within one entry stage.

Section-based construction choice

Transportable enclosure sections can suit installation routes where a complete group chamber would not pass through the building.

Distributed collection points

Return grilles can be located near the occupied zones instead of relying on one intake at the far end.

Group-sequence guidance

Entry indication and selected audible prompts help a batch move through the intended stages together.

응용 프로그램 솔루션

Group-entry selection starts with occupied positions, queue behavior and access to the larger equipment package.

A chamber is labelled for a group, but the intended users block one another's jets.Draw the standing positions and turning space first, then arrange the nozzle zones and occupied-cycle routine around them.
Shift arrivals form a queue that obstructs the gowning route.Compare batch size and full entry-to-exit time, and locate the waiting area outside the door swings and emergency route.
The extended unit cannot reach its installation position in one piece.Choose sectional delivery and planned assembly joints that suit the actual access openings and lifting route.
Filters at an end bay become inaccessible after adjacent equipment is fitted.Reserve withdrawal space for every service section and keep return-grille maintenance separate from the personnel queue.

일반적인 응용 프로그램

Large pharmaceutical gowning roomsSemiconductor shift entrancesDisplay-panel productionAerospace controlled assembly

기술 매개변수

Common reference options for an extended multi-person chamber. Each longitudinal dimension pair describes a separate layout; wider floor plans and additional standing positions use a matched nozzle and recirculation arrangement.

Entry FormatMulti-person batch chamber with defined standing positions
Longitudinal Layout Option AOverall: 1400 × 3000 × 2100 mm; clear chamber: 800 × 2900 × 1980 mm (W × D × H)
Longitudinal Layout Option BOverall: 1450 × 3000 × 2050 mm; clear chamber: 1040 × 2930 × 1910 mm (W × D × H)
Common Three-Metre Nozzle Reference36 sidewall nozzles distributed along the occupied length
Nozzle-Speed Configuration Option25 m/s-class outlet jets
Batch Timer SelectionProgrammable shower cycle; 0–99 s controller option
Air-Circuit FormatDistributed blower/filter sections with local return-air collection
필터 단계Return-air prefilters followed by HEPA final filtration
Material SelectionPowder-coated steel, Type 304 stainless steel or a combined steel/stainless enclosure
Supply Variant380 V AC, 50 Hz
Door SequenceCoordinated entry/shower/exit logic with interlocked doors and emergency release
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Alternative chamber lengths and standing layoutsSectional delivery and assemblyStainless interior or all-stainless bodyAdditional ceiling jet positionsOccupancy indication and spoken instructionsSliding or hinged access doors

The standard selection is a controlled batch-entry arrangement. Continuous walk-through control, extra ceiling outlets and alternative door mechanisms are separate design choices. Occupancy follows the usable standing space and selected operating sequence.

Selection and Installation

Size the actual shift-entry batch

Count the people arriving together and map their positions inside the chamber. More floor area does not by itself establish a larger cleaning capacity: operators need space to turn, receive the intended jets and move out without contacting another garment. Longitudinal and wider group layouts should be compared using occupied positions rather than shell width alone.

Keep batch operation separate from walk-through use

A batch chamber holds a group for a timed sequence before releasing the exit. A continuously moving route requires different sensing, door coordination and exposure timing. Do not assume an interlocked batch model can be used as an open walk-through tunnel simply by increasing the chamber length.

Plan the complete air and electrical package

Select fan sections, nozzle banks, filter area and returns as one system. A jet speed recorded near an outlet is not the velocity reaching a central occupant. Obtain airflow, filter resistance, total input and sound information at the same selected duty rather than multiplying a compact model's figures by the number of bays.

Leave maintenance routes outside the queue

Reserve clearance for the largest filter and fan component, including access at the end bays. Check the route for bringing the enclosure sections into the building and keep service doors clear of waiting personnel. Establish door release during an emergency or power loss, then choose the normal occupancy indication and voice guidance. If paired arrivals can meet the required entry rate, the two-person air shower may use a smaller entrance footprint.

Planning a Multi-Person Cleanroom Air Shower specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat

홈

제품

뉴스

About Us

연락처