A fan filter assembly combining target-specific molecular media with a separate particulate stage for contamination-sensitive process air.
  • Target-Specific Molecular Media
  • Separate Particulate Stage
  • Removable Media Cassette
  • Independent Filter Servicing
견적 요청 제품 찾아보기

상품 소개

The AMC chemical filter FFU adds a removable molecular-media cassette to a fan and final-filter assembly. The chemical stage addresses selected airborne compounds by adsorption or chemisorption, while the separate downstream particulate filter serves a different function. The cassette arrangement allows the gas-phase media to be replaced without treating both stages as a single consumable. Adsorbent chemistry, media depth and process compatibility are selected for the identified contamination profile, rather than assuming one carbon panel handles every gas.

주요 기능

The chemical-media format can be selected around the actual contaminant mixture.

The final particulate stage remains distinct from molecular adsorption.

Cassette withdrawal provides a defined replacement route for spent adsorbent.

Separate consumables allow chemical and particulate maintenance to follow different criteria.

응용 프로그램 솔루션

An acceptable particle count can coexist with a molecular-contamination problem.

Process-sensitive vapours pass through a particle-only filter system.Add media selected for those compounds rather than increasing the particulate-filter class and expecting gas removal.
The chosen carbon medium does not suit the actual contaminant.Use compound-specific adsorption or chemisorption data to select the medium, including the effect of competing gases.
Chemical-media exhaustion is missed during ordinary filter checks.Track exposure and downstream breakthrough separately from the particulate filter's airflow-resistance checks.
A media change causes unnecessary disposal of the final filter.Use the separate service paths and replace each stage according to its own condition and change-out plan.

일반적인 응용 프로그램

Semiconductor cleanroom recirculationReticle and wafer storage environmentsProcess-tool mini-environmentsContamination-sensitive metrology areas

Application suitability depends on the compounds present, the selected media and the required downstream concentration.

기술 매개변수

Common reference choices for the molecular cassette, particulate stage and powered module.

Filtration ArrangementTarget-specific molecular cassette upstream of a separate HEPA or ULPA final filter
Common Molecular-Panel Face Sizes600 × 600 or 600 × 1200 mm; 610 × 610 or 610 × 1220 mm format options
Molecular-Cassette Depth OptionsCommon compact-panel choices: 50, 90 or 150 mm
Adsorbent OptionsActivated carbon for selected organic vapours; impregnated carbon for selected acid or base gases; combined-media cartridges for a defined mixture
Cassette Frame and Seal OptionsAnodized aluminium frame with EPDM or polyurethane perimeter gasket
Final-Filter ConfigurationSeparate mini-pleat particulate stage with gasketed or gel-seal mounting options
Common Fan Supply Options120 V AC, 60 Hz; or 220–240 V AC, 50/60 Hz, single phase, with a matching motor version
Fan-Control OptionsStepped AC drive or variable-speed EC drive serving the combined filter path
Service ArrangementWithdrawable chemical cassette and independently replaceable particulate filter
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Adsorbent formulation for identified gases or vapoursSingle-media or combined-media cassetteHEPA or ULPA particulate stageGas-sampling connections and filter-pressure monitoring

Gas sampling and pressure monitoring answer different questions; neither is an automatic indication that the adsorbent remains effective.

Selection and Installation

Start with the contamination profile

Identify the compounds of concern, their typical and peak concentrations, the permissible downstream level and the source of exposure. Include airflow, temperature, humidity and continuous or intermittent operation. A request for general VOC removal is not a complete media specification: different vapours and gas mixtures can require different adsorbents.

Evaluate capacity as well as initial removal

Compare media performance using the relevant compounds and operating conditions. A high initial removal percentage does not establish useful service life, and a particle-efficiency rating says nothing about gas adsorption. Chemical-media replacement should follow an exposure and breakthrough-monitoring plan; differential pressure alone does not indicate remaining adsorption capacity.

Size the fan for the combined air path

Include both filter stages and the installation's upstream pressure when selecting the operating point. Define the particulate-filter class separately from the molecular requirement, and request air volume, input power and noise for the selected assembly. Reserve space to withdraw the chemical cassette without damaging the final-filter seal or exposing its media.

Match monitoring to the actual risk

Select sampling locations and an analytical method able to detect the target compounds at the required concentration. This cleanroom supply module is not a fume hood, emergency gas scrubber or universal protection against hazardous vapours. Processes that release hazardous substances require their own assessed containment and exhaust system.