クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
ホーム / 製品 / Cleanroom Air Filters / VOC Molecular Air Filter 2600-Class Cylinder
STJH-VOC-MOLECULAR-FILTER-CYL2600

VOC Molecular Air Filter 2600-Class Cylinder

A medium-depth VOC cylinder that increases carbon inventory and airflow for continuous industrial or make-up-air duty.
  • 452 mm carbon cartridge
  • 2500 m3/h rated bank
  • 100-135 Pa initial drop
見積もりリクエスト 製品案内

商品紹介

This 148 x 452 mm activated-carbon cylinder doubles the nominal bank airflow of the compact VOC model to 2500 m3/h. Depending on the selected media and scrim, initial resistance is 100 to 135 Pa. The longer carbon bed is aimed at sustained solvent, odor or mixed-organic exposure in recirculation and make-up air, while remaining easier to house and service than the 595 mm high-capacity model. Carbon grade must be chosen for the actual organic spectrum.

主要な特徴

Mid-range carbon inventory

The 452 mm body carries more adsorbent than the 1300 class, extending useful exposure capacity without the full depth of a 3500-class bank.

Industrial airflow match

Sixteen cylinders deliver 2500 m3/h, serving medium recirculation and outside-air sections with continuous molecular loading.

Media-dependent fan data

A documented 100-135 Pa resistance range highlights the need to check the final carbon and scrim selection against the fan schedule.

技術的なパラメータ

Cylinder Dimensions148 mm diameter x 452 mm length
Rated System Airflow2500 m3/h per 16 cylinders
Initial Pressure Drop100-135 Pa depending on media and scrim
AdsorbentVOC-grade activated carbon
Target ContaminantsSolvent vapors, organic emissions and odors
Cylinder ConstructionABS molecular cartridge
Cylinders per 610 x 610 mm Opening16
Optimum Relative Humidity0-70% RH for VOC carbon family
Optimum TemperatureMaximum 40 C for VOC carbon family
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

Applications

For industrial recirculation, clean manufacturing support and make-up air with moderate ongoing VOC or odor loading. Use separate particulate filtration and measure the relevant organic challenge to predict carbon exhaustion.

Solutions for Your Application

The pressure drop can vary materially with the carbon and internal scrim chosen.Obtain the final resistance point for the selected media fill and verify fan capacity at 2500 m3/h before shipment.
A single broad VOC specification may overlook a difficult high-volatility compound.List priority compounds and concentrations so carbon type, media mass and any second adsorbent stage can be selected deliberately.

利用可能なオプション

Define carbon source, target VOC spectrum, bed loading, frame interface, gasket, service access, prefilter grade, downstream monitoring and replacement threshold.

Planning a VOC Molecular Air Filter 2600-Class Cylinder specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat