Integrated static neutralization
Two ion bars add bipolar ion treatment to the filtered high-velocity air stream.
The shortest ionizing model has a 1300 x 1000 x 2180 mm exterior and a 930 mm deep work zone for one or two people. Two ion bars introduce charged ions into the three-side jet field, while 16 stainless nozzles and two 0.75 kW fan sets perform garment blow-off. It is designed for low-volume electronics access where static neutralization is needed without a long tunnel.
Two ion bars add bipolar ion treatment to the filtered high-velocity air stream.
The 930 mm work-zone depth limits the footprint at a low-traffic semiconductor or optics doorway.
Two fan and HEPA sets serve the single active section with a combined 1.5 kW net power basis.
| External Dimensions | 1300 W x 1000 D x 2180 H mm |
|---|---|
| Work Zone | 800 W x 930 D x 1910 H mm |
| Persons per Cycle | 1-2 |
| Ion Bars | 2 |
| Stainless Nozzles | 16 |
| Nozzle Air Speed | >25 m/s |
| Fan Sets | 2 x 0.75 kW |
| HEPA Filters | 2 x 630 x 630 x 80 mm, 99.995% at 0.3 µm |
| Net Power | 1.5 kW; 380 V, 50 Hz, three phase |
| カスタマイズ | 意図したアプリケーションと動作環境に基づいて利用できます。 |
For semiconductor, display, film, printing and optical production entrances with one or two operators per cycle. Ion balance, decay performance and maintenance intervals should be defined for the site's electrostatic-control program.
Select full stainless or coated-steel exterior, ion-monitoring interface, access control, cycle timing and alternate power arrangement. Verify ionizer maintenance access and process-specific ESD targets.