STJH-HYGIENIC-AIR-HANDLING-UNIT-1101CFM

Hygienic Air Handling Unit 1101 CFM

A compact 1101 CFM hygienic AHU with a 738 x 738 mm cabinet face for cleanable air treatment in small controlled areas.
  • 1101 CFM nominal airflow
  • 738 mm square cabinet face
  • HEPA-ready filtration path
見積もりリクエスト 製品案内

商品紹介

The smallest selected hygienic cabinet combines a 738 mm square face with double-skin construction and a filtration path that can extend from prefiltration to HEPA. Smooth internal surfaces and optional stainless wet-area components support routine cleaning where a standard comfort AHU would be difficult to maintain hygienically.

主要な特徴

Compact hygienic footprint

The small face fits local plant areas while retaining distinct filter, coil and fan service zones.

Cleanable internal path

Smooth interior surfaces reduce ledges where dust and condensate can collect during operation.

Controlled final filtration

A selected HEPA stage can support terminal cleanliness requirements upstream of a small served zone.

技術的なパラメータ

Nominal Airflow1101 CFM
Cabinet Face738 x 738 mm
CasingHygienic double-skin construction
Internal SurfaceSmooth cleanable lining
FiltrationPrefilter through optional HEPA stage
Drain PanSloped drain pan with stainless steel option
Coil DutyCooling and heating coils selected to load
Fan SectionDirect-drive fan option
InstallationIndoor hygienic ventilation system
カスタマイズFilter stages, coil materials and service access can be configured for the intended application and operating environment.

Applications

Small aseptic support rooms, clean preparation spaces, hospital sterile stores and laboratory areas requiring a cleanable air-handling path.

Solutions for Your Application

Condensate and internal ledges can become difficult-to-clean contamination points.Specify smooth liners and a sloped drain pan with suitable access for inspection and cleaning.
The local room needs final filtration without an oversized central unit.Use the compact 1101 CFM casing with the filter stages needed for the served area.

利用可能なオプション

Stainless interior panels, drain-pan upgrades, HEPA filtration, coil coatings, inspection lighting, access-side selection and control sensors are available.

Planning a Hygienic Air Handling Unit 1101 CFM specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。