ホーム / 製品 / クリーンルーム機器 / Fan Filter Unit 770 m³/h 400 Pa High-Static-Pressure
STJH-HIGH-STATIC-PRESSURE-FFU-770-400PA

Fan Filter Unit 770 m³/h 400 Pa High-Static-Pressure

A low-flow, high-pressure FFU operating point for clean-air systems with substantial external resistance.
  • 770 m³/h airflow duty
  • Up to 400 Pa external pressure
  • 1132 x 532 x 440 mm cabinet
見積もりリクエスト 製品案内

商品紹介

This high-performance EC fan filter unit is configured around a 770 m³/h duty and the highest cited external differential pressure in the accepted series: 400 Pa. The 1132 x 532 x 440 mm cabinet is intended for systems where ductwork, prefiltration or dense terminal filtration creates more resistance than a standard ceiling FFU can overcome. The lower airflow point preserves pressure reserve, distinguishing it from the higher-volume models in the group.

主要な特徴

Maximum pressure reserve

The 400 Pa duty is selected for restrictive air paths rather than for maximum free-air volume.

High-performance EC drive

An EC fan supports controllable operation as system resistance changes with filter loading.

Selectable final filtration

H14, U15 or U16 filter options allow the terminal stage to be matched to the clean-air requirement.

技術的なパラメータ

Rated Airflow770 m³/h
Maximum External Differential Pressure400 Pa
External Dimensions1132 x 532 x 440 mm
Fan DriveHigh-performance EC fan
Final Filter OptionsH14, U15 or U16
Operating StrategyPressure-priority duty for high-resistance systems
空気流制御EC speed adjustment to the commissioned system point
InstallationCeiling, plenum or duct-connected clean-air module
Service AccessAccess arrangement selected for the installed housing orientation
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

Applications

Intended for duct-connected cleanrooms, terminal systems with prefilters, high-grade final filters and ceiling networks with substantial pressure loss. The 770 m³/h point should be used where maintaining pressure reserve is more important than maximizing supply volume.

Solutions for Your Application

A conventional FFU loses airflow when connected to a restrictive duct or dense filter stage.Select the 400 Pa operating point and commission the EC fan against the measured resistance of the complete air path.
Choosing a larger airflow model could reduce available pressure where it is needed most.Prioritize this 770 m³/h configuration when pressure margin is the governing design requirement.

利用可能なオプション

Specify H14, U15 or U16 filtration, the duct or plenum connection, control interface and service orientation. Final fan speed must be set from measured system resistance rather than cabinet rating alone.

Planning a Fan Filter Unit 770 m³/h 400 Pa High-Static-Pressure specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat