ホーム / 製品 / クリーンルーム機器 / Floor-Standing Fan Filter Unit 14 m³/min Compact
STJH-FLOOR-STANDING-FFU-14CMM-100V

Floor-Standing Fan Filter Unit 14 m³/min Compact

A short floor-mounted HEPA recirculation unit for small retrofit rooms and local clean zones.
  • 750 x 440 x 830 mm compact cabinet
  • Four airflow steps up to 14 m³/min
  • 43-56 dBA by selected duty
見積もりリクエスト 製品案内

商品紹介

This compact floor-standing FFU fits a 750 x 440 x 830 mm envelope and provides four selectable airflow steps: 6, 10, 12 and 14 m³/min. It uses a 100 V single-phase supply and draws up to 125 W, making it easier to place in a small retrofit workroom than a tall industrial recirculator. The HEPA stage is listed at 99.99% collection at 0.3 µm, with sound increasing from 43 to 56 dBA across the airflow settings.

主要な特徴

Low floor profile

The 830 mm cabinet can sit beside benches or small production cells without the height of a full-room tower.

Four-step adjustment

Discrete 6, 10, 12 and 14 m³/min settings allow output to be matched to the local task.

Single-phase connection

The 100 V, 50/60 Hz electrical basis suits facilities using the cited supply standard.

技術的なパラメータ

External Dimensions750 W x 440 D x 830 H mm
Maximum Airflow14 m³/min
Airflow Steps6, 10, 12 and 14 m³/min
Final FilterHEPA, 99.99% collection at 0.3 µm
Power SupplyAC 100 V, 50/60 Hz
Maximum Power Input125 W
Sound Level43-56 dBA depending on airflow setting
Unit Weight50 kg
InstallationFloor-standing local recirculation or supply unit
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

Applications

Recommended for small retrofit workrooms, benchtop assembly cells, inspection corners and local clean zones where ceiling installation is impractical. The selected airflow step should be confirmed against the room volume, leakage and intended pressure relationship.

Solutions for Your Application

A ceiling FFU cannot be installed in an existing occupied room.Place the compact floor cabinet beside the work zone and select the airflow step that supports the local circulation plan.
Maximum fan speed may create unnecessary noise near operators.Start with the lower 6 or 10 m³/min setting and increase only after checking cleanliness and airflow coverage.

利用可能なオプション

Confirm electrical compatibility, discharge orientation, filter service access and placement beside the process. Mobility accessories and enclosure interfaces can be adapted to the intended room layout.

Planning a Floor-Standing Fan Filter Unit 14 m³/min Compact specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat