The largest separator and manifold body in the series for high-capacity central cleanroom AHUs.
  • 2 in steam and drain connections
  • 343 mm-class body
  • Approximately 80.25 lb base package
見積もりリクエスト 製品案内

商品紹介

This large direct-steam unit uses 2 in NPT steam and drain connections around a 343 mm-class body. The package weighs approximately 80.25 lb before the operator and manifold, requiring more substantial support than the two smaller bodies. Its larger separation volume suits high-capacity central AHUs, provided plant steam is clean, dry and controlled through a correctly sized valve and condensate-return arrangement.

主要な特徴

High steam throughput

The largest inlet and body support central cleanroom AHU humidity loads.

Expanded moisture separation

The larger chamber removes entrained condensate before steam reaches the dispersion grid.

Heavy-duty stainless package

Substantial 300-series construction suits large plant-steam service with engineered supports.

技術的なパラメータ

Steam Inlet2 in NPT
Drain Connection2 in NPT
Body Cross-Section343 mm N-dimension class
Package WeightApproximately 80.25 lb without operator and manifold
Wetted Material300-series stainless steel
Steam SourceConditioned plant steam
ControlHigh-capacity modulating valve
DistributionSingle or multiple manifolds by duct
SupportIndependent engineered mounting
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

Applications

For high-capacity central cleanroom AHUs and large healthcare or process ventilation systems with available conditioned steam.

Solutions for Your Application

Duct sheet metal is expected to carry the 80 lb-class body and manifold without reinforcement.Provide independent supports and distribute loads to the AHU frame or building structure.
High steam flow produces wetting downstream during low-airflow operation.Interlock steam with airflow, limit valve output at turndown and size the dispersion grid for the worst absorption case.

利用可能なオプション

Specify output, steam pressure, valve and actuator, separator orientation, manifold layout, trap, support frame, drain and airflow interlock.

Planning a Direct Steam Injection Humidifier 2-Inch Inlet specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。