ホーム / 製品 / Cleanroom HVAC Systems / Dedicated Outdoor Air System 15000 CFM
STJH-DEDICATED-OUTDOOR-AIR-SYSTEM-15000CFM

Dedicated Outdoor Air System 15000 CFM

A large extended-cabinet DOAS supplying 2000-15000 CFM with 20-55 tons of cooling for central clean manufacturing ventilation.
  • 2000-15000 CFM airflow range
  • 20-55 ton cooling class
  • Extended multi-compressor chassis
見積もりリクエスト 製品案内

商品紹介

The largest selected dedicated outdoor-air system uses a long multi-section cabinet and a 20-55 ton refrigeration range. It is intended for central ventilation and latent-load control across large clean manufacturing buildings, with multiple compressor stages and high-capacity heating options matched to outdoor design conditions.

主要な特徴

Central latent-load treatment

The 15000 CFM platform treats a building-scale outdoor-air stream before distribution to multiple controlled zones.

Multi-stage capacity

Several refrigeration stages support load following across a much broader capacity range than the smaller cabinets.

Large accessory envelope

The extended chassis accommodates substantial heating, filtration and control sections for year-round operation.

技術的なパラメータ

Supply Airflow2000-15000 CFM without energy recovery
Cooling Capacity20-55 tons
Electric Heat Range5-120 kW option
Cabinet ClassLarge extended packaged DOAS
RefrigerationMultiple compressor circuits
Supply FanHigh-capacity variable-speed fan section
FiltrationMulti-stage outdoor-air filter options
Humidity SequenceCooling, dehumidification and reheat options
InstallationEngineered outdoor curb or structural base
カスタマイズCompressor staging, heat source and distribution interfaces can be configured for the intended application and operating environment.

Applications

Large pharmaceutical plants, semiconductor support buildings, central clean manufacturing ventilation and multi-zone healthcare facilities.

Solutions for Your Application

A central ventilation stream varies significantly between occupied and reduced-production periods.Use staged refrigeration and variable fan control to follow the scheduled airflow and moisture load.
The extended cabinet requires careful roof or grade-level coordination.Define structural support, shipping splits, service clearance and duct transitions before final equipment selection.

利用可能なオプション

Multi-stage compressors, reheat, electric or hydronic heat, high-grade filtration, energy-recovery integration, redundant controls and remote monitoring interfaces can be selected.

Planning a Dedicated Outdoor Air System 15000 CFM specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。