A 100% total-exhaust negative-pressure isolator for sterile hazardous-drug compounding with no work-chamber air recirculation.
  • 100% total exhaust
  • Negative-pressure barrier
  • External blower connection
見積もりリクエスト 製品案内

商品紹介

This configuration sends all work-chamber air to an external exhaust blower. It shares the 895 mm work-zone width of the recirculating units but uses a taller exhaust architecture, making it the appropriate family choice when the process requires no return of chamber air.

主要な特徴

No chamber-air recirculation

Air leaves the enclosure through the exhaust route rather than returning to the working chamber.

Hazardous-drug process focus

The pressure and exhaust arrangement is intended for sterile preparations that require containment.

Facility-integrated airflow

An external blower of adequate capacity becomes part of the operating system and must be planned with the cabinet.

技術的なパラメータ

External Dimensions without Base1270 x 825 x 1511 mm
Work Zone895 x 591 x 695 mm
Nominal Width1.2 m
Pressure ModeNegative
Exhaust Architecture100% total exhaust
External Air MoverFacility exhaust blower of suitable capacity
Air Changes20 per minute
Air CleanlinessISO Class 5 HEPA-filtered work zone
Intended CompoundsSterile hazardous drugs
カスタマイズDuct transition, interchange orientation and pharmacy services can be configured for the facility exhaust system.

Applications

Sterile hazardous-drug compounding where all air from the work chamber must be conveyed to the building exhaust system.

Solutions for Your Application

The process strategy does not permit recirculation of work-chamber air.Use the total-exhaust model and discharge the complete chamber airflow through the external connection.
Cabinet performance could be affected by an inadequate facility blower.Size and control the external exhaust system as part of the installation rather than treating it as an unrelated utility.