WFI Distribusi Loop
- Insulated continuous hot circulation
- Drainable low-hold-up user branches
- Integrated thermal control and sanitization interface
Perkenalan produk
This WFI distribution module combines a hygienic circulation pump, insulated supply and return headers, thermal-control exchanger and short point-of-use branches on one open skid. Continuous return flow and measured temperature support the selected hot-storage or periodic thermal-sanitization strategy while keeping serviceable components accessible.
Fitur utama:
Insulated supply and return headers
Hygienic centrifugal circulation pump
Drainable point-of-use branch geometry
Loop heat exchanger with isolated utility circuit
Temperature, pressure and conductivity monitoring
Automated steam or hot-water control interface
Local cabinet for pump and sanitization sequences
Solusi untuk aplikasi Anda
A WFI network must sustain circulation and controlled temperature without creating cool pockets, long branches or difficult-to-drain utility interfaces.
Aplikasi yang Tipis
Parameter teknis
The loop skid is configured around storage temperature, return-temperature target, distribution length, peak demand and sanitization method.
| Bahan inti | 316L stainless steel product-contact tubing, fittings, valve bodies, pump and exchanger surfaces |
|---|---|
| Ketebalan Panel (Panel Thickness) | Control cabinet and skid sheet components typically 1.5–3.0 mm |
| Efektif lebar | Packaged hot-loop skid width typically 1200–2600 mm |
| Panjang maksimum | Packaged distribution module length typically up to 4500 mm |
| Baja menghadap ketebalan | Stainless insulation cladding and cabinet facing typically 0.8–2.0 mm |
| Kepadatan inti (core density) | 316L stainless steel kepadatan sekitar 8000 kg / m3 |
| Konduktivitas Termal (Thermal Conductivity) | Typical hygienic insulation system approximately 0.035–0.045 W/(m·K) |
| Permukaan selesai | Polished or electropolished wetted surfaces with cleanable satin stainless insulation cladding |
| Jenis Bersama | Orbital-welded main tubing with drainable sanitary service connections |
| Customization (Kustomisasi) | Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi. |
Pilihan yang tersedia
Planning a WFI Distribution Loop specification?
Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bahasa Inggris
Bahasa Portugis
Bahasa Spanyol
Bahasa Melayu
Bahasa IndonesiaSaat ini
Bahasa Jerman
Bahasa Turki
Bahasa Vietnam
Bahasa Perancis: Bahasa Perancis
Bahasa Rusia
Bahasa Arab
Bahasa Thailand
Bahasa Jepang
Bahasa Korea