Beranda / Produk / Containment & Biosafety Equipment / Negative-Pressure Containment Isolator 2-Glove with One Airlock
STJH-NEGATIVE-PRESSURE-CONTAINMENT-ISOLATOR-2G-1AL

Negative-Pressure Containment Isolator 2-Glove with One Airlock

A compact two-glove containment isolator pairing a 1410 mm work zone with one material airlock for focused potent-compound tasks.
  • 1410 mm work-zone width
  • Two glove positions
  • Single material airlock
Permintaan untuk kutipan Browse Produk

Perkenalan produk

This model uses the shorter chamber in the frozen family and places one airlock beside a two-glove work zone. The 2196 mm overall width is intended for laboratories that need a defined transfer boundary and negative-pressure handling without allocating floor space to separate entry and exit chambers.

Fitur utama:

Compact contained sequence

One operator can receive, manipulate and remove small batches through a single controlled interchange.

Negative-pressure process zone

The chamber can be configured around an approximately -60 Pa setpoint for potent-material handling.

Front-serviceable layout

A stainless work area and accessible openings support cleaning and routine intervention within a limited footprint.

Parameter teknis

Work-Zone Dimensions1410 x 715 x 629 mm
Overall Dimensions2196 x 955 x 2277 mm with one airlock
Glove Ports2 operator glove positions
Transfer ArrangementOne material airlock
Operating PressureApproximately -60 Pa negative-pressure mode
FiltrationDouble HEPA exhaust arrangement
Chamber ConstructionStainless steel work area and material airlock
Power Supply220-240 V AC, 50-60 Hz, up to 3500 W
Process ModeManual or semi-automated aseptic-toxic handling
Customization (Kustomisasi)Airlock side, glove system, utilities and process interfaces can be configured for the intended potent-compound workflow.

Applications

Small-batch HPAPI weighing, cytostatic formulation, analytical sampling and other focused aseptic-toxic operations requiring a compact negative-pressure barrier.

Solutions for Your Application

A containment isolator must fit a laboratory with restricted frontage.Select the two-glove, one-airlock layout to retain a controlled transfer step within a 2196 mm overall width.
Frequent small lots can lose time when the chamber is oversized.Use the 1410 mm work zone to keep the active process and cleaning area proportional to a one-operator batch.

Pilihan yang tersedia

Airlock orientation, glove material, integrated H2O2 decontamination, utility penetrations, data interfaces and pressure-control recipe may be selected.

Planning a Negative-Pressure Containment Isolator 2-Glove with One Airlock specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.