A large direct-fired makeup-air unit for 28000-48000 CFM central exhaust replacement, built around a 67.9 x 100.3 inch cabinet.
  • 28000-48000 CFM airflow range
  • 67.9 x 100.3 inch large cabinet
  • 75.5 inch fan-module length
Permintaan untuk kutipan Browse Produk

Perkenalan produk

This high-capacity platform uses the largest retained casing and a 75.5 inch forward-curved fan module to serve central exhaust systems. The approximately 4000 lb configured assembly provides conditioned replacement air for large clean manufacturing buildings where several process and room exhaust streams operate together.

Fitur utama:

Central exhaust capacity

The airflow range supports combined replacement air for numerous process hoods, rooms or production exhaust branches.

Large forward-curved fan section

The extended fan module provides the physical envelope needed for high volume and system pressure.

Heavy-duty outdoor package

The large cabinet is intended for a coordinated structural base, service platform and outdoor duct interface.

Parameter teknis

Airflow Range28000-48000 CFM
Cabinet Height67.9 in
Cabinet Width100.3 in
Approximate Weight4000 lb in referenced configuration
Fan Module Length75.5 in forward-curved arrangement
Heating MethodDirect-fired gas
Burner ControlModulating output selected to temperature duty
FiltrationIntake filter section as selected
InstallationEngineered outdoor base or roof support
Customization (Kustomisasi)Fan duty, burner input and cabinet accessories can be configured for the intended application and operating environment.

Applications

Large clean manufacturing plants, central process-exhaust replacement, high-volume pharmaceutical production and multi-zone industrial ventilation.

Solutions for Your Application

A central exhaust network can pull the building substantially negative when replacement air is insufficient.Schedule the 28000-48000 CFM supply against simultaneous exhaust diversity and the required building pressure offset.
The equipment mass and cabinet size exceed ordinary rooftop support assumptions.Coordinate the approximately 4000 lb unit, curb or base, access platform and lifting plan before installation.

Pilihan yang tersedia

High-capacity filtration, variable-frequency fan control, burner modulation, intake and discharge plenums, service vestibules, weather protection and controls are selectable.

Planning a Direct-Fired Makeup Air Unit 48000 CFM Large specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah

Beranda

Produk

Berita

Tentang Kami

Hubungi Kami