Kabinet Keamanan Biologi Kelas II Tipe A2
- Personnel Product and Environmental Protection
- HEPA-Filtered Downflow
- Negative-Pressure Contaminated Plenums
- Recirculating A2 Airflow
Perkenalan produk
The Type A2 cabinet draws room air inward at the front grille while HEPA-filtered downflow protects the work zone. A portion of the filtered air is recirculated and the balance is exhausted through a HEPA stage, either into the room or through an appropriate canopy connection. Contaminated plenums are maintained under negative pressure or surrounded by negative-pressure sections. The cabinet is selected and installed for biological particulate work; volatile chemical use requires a separately evaluated exhaust strategy.
Fitur utama:
Vertical filtered downflow limits cross-contamination across the product zone.
Negative-pressure plenum design provides a fail-safe boundary around contaminated air paths.
A motorized or counterbalanced sash maintains the selected operating height.
Independent inflow and downflow sensing supports real-time airflow monitoring.
Solusi untuk aplikasi Anda
A Type A2 cabinet must balance operator capture and clean product downflow while keeping recirculated air paths safely enclosed.
Aplikasi yang Tipis
Parameter teknis
Typical configurable construction ranges for a Class II Type A2 biological safety cabinet are listed below.
| Bahan inti | SUS304 single-piece work-zone liner with powder-coated steel outer shell and mineral-wool acoustic fan enclosure |
|---|---|
| Ketebalan Panel (Panel Thickness) | 30-60 mm double-wall cabinet and plenum sections |
| Efektif lebar | 900 - 1800 mm lebar kerja yang jelas |
| Panjang maksimum | Up to 2400 mm overall cabinet height |
| Baja menghadap ketebalan | 1.0-1.5 mm SUS304 inner liner; 0.9-1.2 mm outer steel |
| Kepadatan inti (core density) | 80 - 120 kg / m3 mineral-wol akustik infill |
| Konduktivitas Termal (Thermal Conductivity) | 0,035 - 0,045 W / (m · K) untuk infill akustik |
| Permukaan selesai | Fine-brushed SUS304 work zone with white epoxy-polyester outer coating |
| Jenis Bersama | Welded inner liner with negative-pressure plenum joints and gasketed supply and exhaust HEPA frames |
| Customization (Kustomisasi) | Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi. |
Pilihan yang tersedia
Planning a Class II Type A2 Biological Safety Cabinet specification?
Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bahasa Inggris
Bahasa Portugis
Bahasa Spanyol
Bahasa Melayu
Bahasa IndonesiaSaat ini
Bahasa Jerman
Bahasa Turki
Bahasa Vietnam
Bahasa Perancis: Bahasa Perancis
Bahasa Rusia
Bahasa Arab
Bahasa Thailand
Bahasa Jepang
Bahasa Korea