Pemasok One-Stop Anda untuk Peralatan Cleanroom dan Fasilitas Aseptik EsensialDukungan proyek internasional
Open mobile navigationClose mobile navigation
Cleanroom HVAC dan Peralatan Penanganan Udara

Pompa sirkulasi air dingin-dingin

A base-mounted end-suction centrifugal pump that circulates chilled water between the chiller, air-handling coils and process cooling branches.
  • Stable Hydronic Flow
  • Back-Pull-Out Service
  • Variable-Speed Ready
  • Rigid Base Alignment
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The chilled-water pump couples a single-stage cast-iron volute to a high-efficiency motor on a common baseplate. Its end-suction geometry provides a straight inlet path, while the top discharge fits conventional mechanical-room headers. A guarded flexible coupling accommodates minor alignment tolerance and allows the rotating assembly to be serviced without disturbing connected pipework when a back-pull-out arrangement is selected.

Fitur utama:

A smoothly contoured volute converts impeller velocity into useful system pressure with limited hydraulic loss.

Common-base motor and pump alignment reduces vibration transmitted to cleanroom piping networks.

Mechanical-seal and coupling access supports planned maintenance without cutting the main suction and discharge lines.

Variable-frequency drive compatibility follows two-way valve demand and reduces unnecessary throttling energy.

Solusi untuk aplikasi Anda

Chilled-water service requires correct flow, low vibration and reliable seals across continuously changing cooling demand.

Oversized constant-speed pumps waste energy against throttled valves.A variable-speed motor adjusts differential pressure and flow to actual coil demand.
Poor suction conditions create cavitation noise and impeller damage.A straight end-suction inlet and correctly selected NPSH margin support stable flow into the eye.
Motor-pump misalignment shortens bearing and seal life.A machined common base and guarded flexible coupling preserve shaft alignment.
Seal replacement causes extended system shutdown.Back-pull-out access removes the rotating assembly while the volute remains connected to the piping.

Aplikasi yang Tipis

Primary chilled-water loopsSecondary variable-flow distributionCleanroom AHU coil circuitsProcess-equipment cooling waterLow-temperature laboratory systems

Parameter teknis

Typical mechanical construction for a cleanroom chilled-water pump set is summarized below.

Bahan intiCast-iron volute with stainless steel or bronze impeller and steel shaft
Ketebalan Panel (Panel Thickness)8-16 mm fabricated steel baseplate thickness
Efektif lebar350-900 mm typical pump-set width
Panjang maksimumUp to 2400 mm including motor and coupling
Baja menghadap ketebalan1.5-2.5 mm removable coupling-guard sheet
Kepadatan inti (core density)Approximately 7000-7300 kg/m³ for cast-iron volute material
Konduktivitas Termal (Thermal Conductivity)Approximately 45-55 W/(m·K) for cast-iron wetted casing
Permukaan selesaiBlue epoxy coating on cast iron with painted steel base
Jenis BersamaFlanged suction/discharge, flexible shaft coupling and bolted base mounts
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

Stainless steel or bronze impellerMechanical-seal material combinationsVariable-frequency drive and differential-pressure sensorSingle duty, duty-standby or twin-pump skid

Planning a Chilled-Water Circulation Pump specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah

Rumah > Produk-produk >

Produk-produk

Berita Berita

Tentang kami