Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Équipement Cleanroom / Cleanroom Personnel Airlock 52 × 44 in Passive
STJH-PERSONNEL-AIRLOCK-52X44-PASSIVE

Cleanroom Personnel Airlock 52 × 44 in Passive

A compact neutral-air personnel vestibule that controls door sequencing without an active fan-filter unit.
  • One-person compact chamber
  • No integral blower
  • Emergency interlock release
Demander un devis. Browse les produits

Introduction de produit

This passive personnel airlock uses a 52 x 44 in nominal footprint and a 39.5 x 36 in usable chamber for one-person transitions. Interlocked doors limit simultaneous opening, while an interior emergency release and maintenance bypass support safe operation. Because it has no blower, it suits facilities where the surrounding HVAC system and gowning procedure provide the pressure and cleanliness strategy.

Key Features

Neutral transition zone

The unpressurized chamber separates door openings while avoiding an additional active airflow source.

Controlled door sequence

The interlock blocks simultaneous access and includes an emergency release from inside the enclosure.

Simple retrofit service

A powder-coated body and no FFU reduce overhead filter-service requirements at constrained entries.

Paramètres techniques

Nominal Footprint52 W x 44 D in
Overall Height90 in nominal
Usable Chamber39.5 W x 36 D x 83 H in
Door Clearance36 W x 81 H in
OccupancyOne person
Pressure ModeNon-pressurized
BlowerNone
Door ControlElectronic interlock with emergency release
ConstructionPowder-coated steel with framed panel doors
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Applications

For basic personnel transitions between controlled rooms where a neutral pause and disciplined door sequence are required. The surrounding HVAC design must supply any necessary pressure cascade because this model does not actively purge or pressurize its chamber.

Solutions for Your Application

Opening adjacent room doors together disrupts the pressure boundary.Use the interlock to force one-door-at-a-time passage through the neutral chamber.
A powered FFU would add maintenance where no active purge is needed.Select the passive no-blower format and rely on the validated room HVAC pressure scheme.

Options disponibles

Choose powder-coated or stainless construction, panel material, access controls, indicator lights and door handing. Voltage is required for controls even though the chamber has no blower.

Planning a Cleanroom Personnel Airlock 52 × 44 in Passive specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact