Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Équipement Cleanroom / Negative-Pressure HEPA Filtration Unit 16 × 48 in
STJH-NEGATIVE-PRESSURE-HEPA-UNIT-16X48

Negative-Pressure HEPA Filtration Unit 16 × 48 in

The longest narrow reverse-flow model, providing a 4.5 ft² HEPA collection face for broad exhaust zones.
  • 47.63 in long chassis
  • 4.5 ft² active filter face
  • Narrow negative-pressure pickup
Demander un devis. Browse les produits

Introduction de produit

The 16 x 48 in configuration maximizes capture length within the narrow reverse-flow family. Its 4.5 ft² active filter face spans a 47.63 in cabinet depth while keeping the housing width to 15.7 in. A backward-curved variable-speed PSC blower draws room air through the MERV 7 and HEPA stages for broad isolation or powder-containment coverage.

Key Features

Broad linear collection

The 48 in length distributes exhaust pickup along a long work or maintenance zone.

Room-side dust control

A collector pan sits beneath the accessible filter path for service within the enclosure.

Ductless ceiling integration

The reverse-flow chassis can operate as a ceiling module without a separate downstream duct section.

Paramètres techniques

Nominal Size16 x 48 in
Product Dimensions15.7 W x 47.63 D x 16.125 H in
Active Filter Area4.5 ft²
AirflowNegative-pressure reverse flow
Final FilterHEPA, 99.99% at 0.3 µm
PrefilterMERV 7
Motor1/4 hp PSC
Blower and ControlBackward-curved, variable speed
ConstructionPowder-coated steel; room-side collector pan
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Applications

Used over long isolation enclosures, broad repair bays and controlled powder-handling zones. The extended pickup can reduce the number of small exhaust modules when ceiling geometry permits one long unit.

Solutions for Your Application

Multiple short exhaust points create uneven collection along a long enclosure.Apply the continuous 4.5 ft² filter face across the principal contaminant-release line.
A long suspended cabinet may conflict with ceiling supports.Map the 47.63 in body against the support grid and use dedicated suspension points where required.

Options disponibles

Select surface frame, inlet adapter, filter alarm, suspension kit and fan controller. Electrical data and final duty should be established for the installed filter resistance.

Planning a Negative-Pressure HEPA Filtration Unit 16 × 48 in specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat