Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Cleanroom HVAC Systems / Direct-Fired Makeup Air Unit 3200 CFM Compact
STJH-MAKEUP-AIR-UNIT-3200CFM-39X34

Direct-Fired Makeup Air Unit 3200 CFM Compact

A compact direct-fired makeup air unit covering 800-3200 CFM in a 39 x 33.7 inch cabinet for small exhaust replacement duties.
  • 800-3200 CFM airflow range
  • 39 x 33.7 inch cabinet face
  • Compact direct-fired heating section
Demander un devis. Browse les produits

Introduction de produit

This smallest retained cabinet tempers replacement air for systems exhausting between 800 and 3200 CFM. Its approximately 700 lb configured mass and 39 x 33.7 inch face make it practical for a local utility or laboratory exhaust system that does not need a large central makeup-air plant.

Key Features

Local exhaust replacement

The airflow range matches smaller extraction systems without forcing a large unit to operate at the bottom of its capacity.

Compact burner package

Direct-fired heating tempers cold outdoor air within a short cabinet arrangement.

Defined small-unit weight

An approximate 700 lb configured weight supports roof curb or housekeeping-pad selection.

Paramètres techniques

Airflow Range800-3200 CFM
Cabinet Height39 in
Cabinet Width33.7 in
Approximate Weight700 lb in referenced configuration
Heating MethodDirect-fired gas
Thermal Efficiency ClassApproximately 92% class
Fan ArrangementForward-curved supply fan option
Control RangeModulating burner and fan controls as selected
InstallationOutdoor roof or grade-mounted arrangement
CustomisationHeating capacity, controls and intake accessories can be configured for the intended application and operating environment.

Applications

Small laboratory exhaust replacement, clean-support utility rooms, controlled packaging exhaust and local industrial ventilation systems.

Solutions for Your Application

Unconditioned replacement air causes winter drafts and room pressure instability.Match the supply airflow to the exhaust rate and modulate the direct-fired heating section to the required discharge condition.
A central-size unit would be too heavy and difficult to turn down for the local system.Use the compact 800-3200 CFM platform close to its intended operating band.

Options disponibles

Gas train, burner modulation, intake hood, filter section, discharge orientation, fan controls and roof-curb arrangement can be selected.

Planning a Direct-Fired Makeup Air Unit 3200 CFM Compact specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact