Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Équipement Cleanroom / Fan Filter Unit 1555 m³/h 320 Pa High-Static-Pressure
STJH-HIGH-STATIC-PRESSURE-FFU-1555-320PA

Fan Filter Unit 1555 m³/h 320 Pa High-Static-Pressure

A large square FFU for broad clean-air coverage with a 1555 m³/h, 320 Pa balanced duty.
  • 1132 x 1132 mm square footprint
  • 1555 m³/h airflow
  • 320 Pa external pressure capability
Demander un devis. Browse les produits

Introduction de produit

This 1132 x 1132 mm balanced-performance module provides the largest filter footprint and airflow of the three accepted high-pressure models. At a 0.3 m/s face velocity it delivers 1555 m³/h while retaining 320 Pa of available external differential pressure. The square geometry is intended for broad ceiling bays where one module must cover more area but still overcome meaningful system resistance.

Key Features

Large-area supply

The square 1132 mm footprint distributes filtered air across a wider ceiling zone than the narrow high-performance cabinets.

Documented face velocity

The 0.3 m/s operating point links the large filter face to a defined 1555 m³/h supply duty.

Useful pressure reserve

A 320 Pa external capability supports connected resistance while prioritizing higher air volume.

Paramètres techniques

Rated Airflow1555 m³/h
Maximum External Differential Pressure320 Pa
Module Footprint1132 x 1132 mm
Reference Face Velocity0.3 m/s
Fan DriveEC fan configured for balanced performance
Final Filter SelectionHigh-efficiency filter matched to the application
Contrôle AirflowVariable EC speed to commissioned duty
InstallationFull-perimeter supported cleanroom ceiling bay
Service AccessPlanned around the large square housing
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Applications

Designed for large cleanroom ceiling bays, broad process tools and localized unidirectional-flow zones that need more coverage per unit. The supporting grid, lifting route and return-air path must be sized for the larger footprint and 1555 m³/h supply volume.

Solutions for Your Application

Narrow high-pressure FFUs would require too many modules across a broad bay.Use the 1132 mm square face to consolidate coverage while retaining 320 Pa of available pressure.
A large airflow module could overwhelm an undersized return path.Confirm the room return capacity and commission the EC fan at the documented 0.3 m/s reference point or the verified project duty.

Options disponibles

Specify the high-efficiency filter, control interface, sealing system and service arrangement. Structural and airflow coordination should reflect the full 1132 mm square footprint.

Planning a Fan Filter Unit 1555 m³/h 320 Pa High-Static-Pressure specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact