Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Cleanroom HVAC Systems / Gasketed Plate-and-Frame Heat Exchanger 50.4 ft2
STJH-GASKETED-PLATE-HEAT-EXCHANGER-504FT2

Gasketed Plate-and-Frame Heat Exchanger 50.4 ft2

A large T10-class gasketed exchanger with 20 Alloy 316 plates, 50.4 ft2 area and 4 inch Class 150 flanges.
  • 50.4 ft2 transfer area
  • 20 Alloy 316 plates
  • 4 inch Class 150 flanges
Demander un devis. Browse les produits

Introduction de produit

The large plate-and-frame unit uses broader geometry and 20 plates to provide 50.4 ft2 of transfer area. Four-inch ASME Class 150 flanges support substantially greater flow for central clean-manufacturing chilled-water decoupling and process heat exchange.

Key Features

Large-flow separation

Broad plate channels and flanged connections serve central utility flow while isolating the two circuits.

Openable high-capacity frame

The large plate pack remains accessible for mechanical cleaning and gasket service.

Central skid integration

Flanged nozzles connect to large-bore plant piping and packaged utility assemblies.

Paramètres techniques

Plate Count20
Heat-Transfer Area50.4 ft2
Connection4 in ASME Class 150 flange
Plate MaterialAlloy 316
Frame ClassLarge T10-type gasketed frame
Circuit ArrangementTwo isolated counterflow paths
Flow DutyHigh-volume utility service
MaintenanceOpenable plate pack
InstallationEngineered floor or skid base
CustomisationPlate pattern, gasket compound and flange orientation can be configured for the intended application and operating environment.

Applications

Large clean-manufacturing chilled-water decoupling, central process heat exchange, heat-pump isolation and pharmaceutical utility plants.

Solutions for Your Application

Two large utility loops must exchange heat without cross-contamination.Use the separated Alloy 316 plate channels and monitor pressure on both circuits.
High flow makes small threaded connections and narrow plate packs restrictive.Use the 4 inch flanges and 50.4 ft2 broad plate pack sized to acceptable pressure drop.

Options disponibles

Additional plates, alternate gasket elastomer, higher frame rating, insulation, lifting points, drain tray and nozzle orientation can be selected.

Planning a Gasketed Plate-and-Frame Heat Exchanger 50.4 ft2 specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact