Accueil / Produits / Cleanroom Air Filters / AMC Filtration System 4-Cell 1100 m3/h
STJH-AMC-FILTRATION-SYSTEM-4CELL-1100

AMC Filtration System 4-Cell 1100 m3/h

A compact single-pass four-cell molecular system for local rooms and process enclosures with controlled corrosion risk.
  • Four deep-bed cells
  • 1100 m3/h airflow
  • 0.141 m3 media volume
Demander un devis. Browse les produits

Introduction de produit

This four-cell system packages 0.141 m3 of adsorbent within a 610 x 700 x 810 mm internal envelope. At 1100 m3/h it provides a documented 0.5 s contact time and 105 Pa pressure drop, making it the smallest member of the three-system group. The compact flow suits local supply-air or recirculation duties, while media selection remains dependent on whether acids, bases, sulfur gases or VOCs dominate the site challenge.

Key Features

Compact room-scale capacity

The four-cell arrangement serves localized protection without the footprint of the eight- or sixteen-cell systems.

Defined contact time

At rated flow the adsorbent bed provides 0.5 s for gas transfer and reaction.

Selectable gas chemistry

Individual cells can use media selected around the documented contaminant mixture.

Paramètres techniques

Internal Dimensions610 x 700 x 810 mm
Adsorbent Cells4
Media Volume0.141 m3
Rated Airflow1100 m3/h
Contact Time0.5 s
Pressure Drop105 Pa
Operating ModeSingle-pass or selected recirculation duty
Media TypeContaminant-specific deep-bed adsorbent
Primary ScaleSmall room or process enclosure
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Applications

For small control rooms, process enclosures and localized corrosion-control supply systems with defined airborne molecular contamination.

Solutions for Your Application

The four-cell media inventory is undersized for a high infiltration or process emission load.Calculate gas mass loading against 0.141 m3 of media and select the eight-cell system if the required life cannot be met.
Actual flow exceeds 1100 m3/h and reduces contact time below the design basis.Balance the branch at rated flow or use a larger system that preserves the 0.5 s contact period.

Options disponibles

Specify target gases, media blend by cell, prefilter, fan arrangement, sensors, cabinet finish, access and replacement interval.

Planning a AMC Filtration System 4-Cell 1100 m3/h specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact