Photomètre aérosol
- Real-time aerosol penetration measurement for filter scans.
- Controlled sample flow with automatic zeroing.
- Portable interface for cleanroom validation teams.
Introduction de produit
This aerosol photometer draws a controlled sample through a light-scattering chamber and reports challenge concentration or filter penetration in real time. Dedicated upstream, downstream and clear-flow connections support the complete integrity-test sequence, while a color interface presents the baseline, alarm threshold and live scan response. The rugged portable enclosure accommodates field validation work in cleanrooms, laboratories and containment facilities.
Key Features
Automatic zero and upstream normalization reduce setup steps before scanning.
Regulated sample flow supports repeatable probe response and leak localization.
Selectable audible and visual alarms alert the operator at the chosen threshold.
Dedicated upstream, downstream and clear ports organize the sampling sequence.
Portable enclosure and probe interface support room-to-room validation work.
Des solutions pour votre application
A dependable integrity scan requires stable sample flow, a clean zero reference and immediate indication of localized aerosol penetration.
Les applications typiques
Paramètres techniques
Common construction values for portable aerosol photometers are summarized below; optical range, flow control and data features vary with the selected configuration.
| Matériaux de base | Forward-scattering optical chamber, regulated sampling pump, reference filtration path and digital control electronics |
|---|---|
| Panneau épaisseur | Typically 1.0-2.0 mm for the protective enclosure panels |
| Largeur effective | Approximately 240-320 mm depending on display and valve configuration |
| Longueur maximale | Approximately 320-420 mm including sampling fittings and protective handle |
| Acier face épaisseur | Typiquement 1,0 - 1,5 mm revêtement en acier inoxydable ou en poudrepar |
| Densité Core | Approximately 7900-8000 kg/m³ for stainless sample-path and enclosure components |
| Conductivité thermique | Environ 14 - 17 W / (m · K) pour les composants de chemin d'échantillonnage inoxydable |
| surface finie | Light-gray powder-coated enclosure with dark bezel, color display and stainless sampling fittings |
| Type joint | Barbed or quick-connect upstream, downstream and clear sampling ports with locking probe connector |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Aerosol Photometer specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Le portugais
espagnol
Le malais
Indonésien
Allemand
Le turc
Le vietnamien
FrançaisCurrent
russe
Arabe
Thaïlandais
Japonais
Coréen