Startseite / Produkte / Cleanroom HVAC Systems / Cleanroom Direct-Expansion Air Conditioning Unit 81 kW
STJH-CLEANROOM-DX-AIR-CONDITIONING-81KW

Cleanroom Direct-Expansion Air Conditioning Unit 81 kW

An 80.7 kW gross-cooling precision DX unit with 7.2 m3/s airflow and two 2.41 l/s glycol heat-rejection paths.
  • 80.7 kW gross cooling
  • 7.2 m3/s airflow
  • Two 2.41 l/s glycol paths

Produkteinführung

The mid-capacity DX selection increases gross cooling to 80.7 kW and nominal airflow to 7.2 m3/s. Its documented twin 2.41 l/s glycol flows and R410A refrigeration match a larger coil and compressor selection for cleanrooms with medium-to-high sensible load.

Key Features

Higher mid-range output

The coil and compressor combination adds cooling capacity above the 73 kW build without moving to the largest selection.

Twin heat-rejection flows

Two glycol paths support the dual refrigeration circuits and their external heat-rejection connection.

Precision air-volume control

EC fan speed can be matched to the 7.2 m3/s distribution requirement and filter condition.

Technische Parameter

Gross Cooling Capacity80.7 kW
Nominal Airflow7.2 m3/s
Glycol Flow2 x 2.41 l/s
RefrigerantR410A
Compressor TypeScroll
Refrigerant Circuits2
Fan TypeEC variable-speed array
Humidity ControlDehumidification with selectable reheat
Heat RejectionRemote glycol-cooled arrangement
CustomisierungGlycol conditions, discharge arrangement and control sequence can be configured for the intended application and operating environment.

Applications

Medium-to-high-load cleanrooms, electronics production, precision laboratories and technical suites requiring close temperature and humidity control.

Solutions for Your Application

The process load sits above the smaller DX model but does not justify the largest cabinet selection.Apply the 80.7 kW build at the verified sensible and latent design point.
Heat-rejection pressure loss can differ between the two glycol branches.Balance both 2.41 l/s paths and provide accessible strainers and isolation at the unit connections.

Verfügbare Optionen

Air discharge direction, reheat, humidification, filtration, glycol pumping accessories, compressor controls and monitoring interfaces can be selected.

Planning a Cleanroom Direct-Expansion Air Conditioning Unit 81 kW specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Sprechen Sie mit unserem Team
E-Mail uns WhatsApp WeChat

Startseite

Produkte

Neuigkeiten

Über uns

Kontakt