Cleanroom Direct-Expansion Air Conditioning Unit 81 kW

An 80.7 kW gross-cooling precision DX unit with 7.2 m3/s airflow and two 2.41 l/s glycol heat-rejection paths.
  • 80.7 kW gross cooling
  • 7.2 m3/s airflow
  • Two 2.41 l/s glycol paths
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The mid-capacity DX selection increases gross cooling to 80.7 kW and nominal airflow to 7.2 m3/s. Its documented twin 2.41 l/s glycol flows and R410A refrigeration match a larger coil and compressor selection for cleanrooms with medium-to-high sensible load.

Ciri-ciri Utama

Higher mid-range output

The coil and compressor combination adds cooling capacity above the 73 kW build without moving to the largest selection.

Twin heat-rejection flows

Two glycol paths support the dual refrigeration circuits and their external heat-rejection connection.

Precision air-volume control

EC fan speed can be matched to the 7.2 m3/s distribution requirement and filter condition.

Parameter teknikal

Gross Cooling Capacity80.7 kW
Nominal Airflow7.2 m3/s
Glycol Flow2 x 2.41 l/s
RefrigerantR410A
Compressor TypeScroll
Refrigerant Circuits2
Fan TypeEC variable-speed array
Humidity ControlDehumidification with selectable reheat
Heat RejectionRemote glycol-cooled arrangement
PenyesuaianGlycol conditions, discharge arrangement and control sequence can be configured for the intended application and operating environment.

Applications

Medium-to-high-load cleanrooms, electronics production, precision laboratories and technical suites requiring close temperature and humidity control.

Solutions for Your Application

The process load sits above the smaller DX model but does not justify the largest cabinet selection.Apply the 80.7 kW build at the verified sensible and latent design point.
Heat-rejection pressure loss can differ between the two glycol branches.Balance both 2.41 l/s paths and provide accessible strainers and isolation at the unit connections.

Pilihan yang boleh didapati

Air discharge direction, reheat, humidification, filtration, glycol pumping accessories, compressor controls and monitoring interfaces can be selected.