موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
الرئيسية / المنتجات / معدات الغرف النظيفة / Vertical Laminar Flow Clean Bench 6 ft
STJH-VERTICAL-CLEAN-BENCH-6FT

Vertical Laminar Flow Clean Bench 6 ft

A wide vertical clean bench for large equipment layouts and coordinated non-hazardous assembly work.
  • 6 ft extended work zone
  • Large-instrument capacity
  • Vertical ISO Class 5 downflow
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This 6 ft model extends the protected work surface for long assemblies, multiple instruments or two coordinated task positions. It retains the vertical 45-65 fpm HEPA-filtered downflow and tempered-glass enclosure of the smaller series. The broad front opening demands careful loading so large equipment does not create stagnant areas or divide the downflow over critical components.

الخصائص الرئيسية

Extended process layout

The six-foot surface accommodates long assemblies or multiple fixtures without crowding the critical zone.

Coordinated work positions

The wider opening can support two defined stations when procedures prevent cross-traffic between operators.

Product protection across width

A full-width diffuser distributes HEPA-filtered downflow above the work area.

المعلمات الفنية

Nominal Width6 ft
Airflow DirectionVertical downflow
Downflow Velocity45-65 fpm
Final FilterHEPA, 99.99% at 0.3 µm
Work-Zone ConditionISO Class 5
Sash Opening9.4 in nominal
ConstructionPowder-coated metal with tempered glass
Blower ControlVariable-speed solid-state control
Work ArrangementLarge single process or coordinated dual positions
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

For large sterile assemblies, multi-instrument life-science work and wide non-hazardous device processes. Define operator zones and recheck airflow with the actual fixtures installed across the six-foot surface.

Solutions for Your Application

Long assemblies extend outside a four-foot protected zone.Use the six-foot bench so the entire critical work remains beneath the filtered diffuser.
Two operators disturb each other's workflow and downflow.Mark separate positions and arrange materials so hands and equipment do not cross between critical zones.

الخيارات المتاحة

Choose airflow monitoring, UV package, stand type, electrical configuration and work-surface finish. Utility port quantity and location can be adapted to the installed instruments.

Planning a Vertical Laminar Flow Clean Bench 6 ft specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا