A half-width molecular V-bank that fits narrow AHU cells while providing 1500 m3/h broad-spectrum gas control.
  • 1500 m3/h half-module duty
  • 80 Pa clean resistance
  • 300 mm molded V-bank
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This 592 x 287 x 300 mm model packages activated-carbon pleats in a molded V-bank frame for air handlers that cannot accept a full-square cartridge. At 1500 m3/h and 80 Pa initial resistance, it gives designers a documented half-module duty for mixed urban or process gases. Its molecular function must be paired with a separate particulate stage where dust control is also required, and service life should be set from the actual gas challenge rather than pressure drop alone.

الخصائص الرئيسية

Narrow-bank fit

The 287 mm face width lets a molecular stage occupy half-module positions, perimeter cells or compact retrofit racks without forcing a larger housing.

Defined fan load

An 80 Pa initial pressure drop at 1500 m3/h provides a clear starting point for checking the available static pressure of a smaller AHU.

Broad external-gas coverage

The activated-carbon platform is intended for low concentrations of ozone, nitrogen dioxide, sulfur dioxide and representative VOCs such as toluene.

المعلمات الفنية

Dimensions592 x 287 x 300 mm
Rated Airflow1500 m3/h
Initial Pressure Drop80 Pa
Molecular MediaBroad-spectrum activated carbon
Target ContaminantsOzone, NO2, SO2 and VOCs
Frame ConstructionMolded plastic V-bank
Maximum Operating Temperature40 C
Maximum Relative Humidity70% RH
Recommended Final Pressure Drop160 Pa; gas capacity remains the replacement basis
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

Suited to narrow make-up-air and recirculation tracks serving clean manufacturing, laboratories or urban-air intakes where gaseous pollution must be reduced before final particle filtration. Confirm the contaminant mixture and expected concentration before choosing the carbon formulation.

Solutions for Your Application

A full-size molecular cartridge will not fit the available half-module opening.Use the 592 x 287 mm face and verify the 300 mm track depth, gasket contact and access direction against the existing rack.
Operators may wait for a pressure-rise signal even after the carbon is exhausted.Set the change interval from gas monitoring, exposure history or media analysis because adsorption capacity can be consumed while resistance remains low.

الخيارات المتاحة

Specify gas target, media formulation, airflow direction, gasket side, front- or side-access rack, upstream particulate protection and a contaminant-based replacement plan.

Planning a V-Bank Activated Carbon Filter 592 × 287 mm specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.