موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
الرئيسية / المنتجات / معدات الغرف النظيفة / Negative-Pressure Weighing Booth 2 ft Ducted
STJH-NEGATIVE-PRESSURE-WEIGHING-2FT-DUCTED

Negative-Pressure Weighing Booth 2 ft Ducted

A narrow externally exhausted enclosure for small-batch weighing where filtered air must leave the room.
  • Compact two-foot width
  • Remote-blower exhaust
  • 23 or 30 inch work depth
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This two-foot weighing booth captures powder close to the balance and routes the HEPA-filtered exhaust to a remote blower. The ducted arrangement keeps blower heat and noise away from the work zone while supporting facilities that prohibit room-air recirculation. Choice of 23 or 30 inch interior depth accommodates compact balances or deeper weighing equipment.

الخصائص الرئيسية

Externally discharged air

The exhaust connection carries filtered air out through the building system instead of returning it to the room.

Quiet working zone

Locating the blower remotely reduces motor heat and sound at the weighing position.

Depth selection

Two interior depths let the enclosure fit either a small analytical balance or deeper process equipment.

المعلمات الفنية

Nominal Width2 ft
Interior Depth23 or 30 in
Airflow ModeNegative-pressure capture
ExhaustDucted to remote blower
Primary FilterHEPA
BlowerRemote, by exhaust-system design
Work SurfaceChemical-resistant or stainless steel option
Airflow MonitoringDigital monitor option
Typical LoadSmall balance and powder containers
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

For small pharmaceutical, compounding and laboratory powder-weighing stations connected to a dedicated exhaust system. The remote blower and duct path should be sized for the enclosure pressure loss.

Solutions for Your Application

Recirculating filtered air is not permitted for the handled powder.Connect the booth to a remote blower so captured air is discharged through the facility exhaust path.
A full-size enclosure consumes too much bench space for a single balance.Use the two-foot body with the work depth selected around the balance footprint.

الخيارات المتاحة

Select 23 or 30 inch depth, work-surface material, service fittings, airflow monitor and duct transition. Remote blower duty is coordinated with the installed ductwork.

Planning a Negative-Pressure Weighing Booth 2 ft Ducted specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا